Back to Search Start Over

Transradial intra-aortic catheter looping in the angioplasty of severe intracranial symptomatic arteriosclerotic diseases.

Authors :
Xu GQ
Xia JC
Cai DY
Yang BW
Zhao TY
Xue JY
Wang ZL
Li TX
Gao BL
Source :
Frontiers in neurology [Front Neurol] 2023 Oct 13; Vol. 14, pp. 1226306. Date of Electronic Publication: 2023 Oct 13 (Print Publication: 2023).
Publication Year :
2023

Abstract

Purpose: This study aims to investigate the effect and feasibility of intra-aortic catheter looping via transradial access in angioplasty for symptomatic intracranial severe (>70%) atherosclerotic stenosis or occlusion of large arteries (SISOLAs).<br />Materials and Methods: Patients with SISOLAs who underwent transradial endovascular angioplasty using the catheter looping technique in the ascending aorta were retrospectively enrolled. The clinical data and treatment outcomes were analyzed.<br />Results: Fifteen patients aged 48-71 years were enrolled in this study. Left vertebrobasilar artery occlusion was present in 1 (6.7%) patient, severe left middle cerebral artery stenosis in 7 (46.7%) patients, severe left internal carotid artery (ICA) stenosis of the ophthalmic segment in 4 (26.7%) patients, severe left ICA stenosis of the cavernous segment in 2 (13.3%) patients, and severe right middle cerebral artery stenosis in 2 (13.3%) patients. The arterial stenosis ranged from 70 to 92% (mean 86%) before stenting. The looping of a guiding catheter in the ascending aorta via transradial access for angioplasty was successful in all patients (100%). The vertebral artery intracranial segment occlusion was successfully recanalized, while severe stenosis in the remaining 14 patients was successfully eliminated. After endovascular recanalization, the residual stenosis was reduced by 12-26% (median 18%). No puncture-related complications or surgical-related neurological complications occurred in these patients. In the follow-up angiography conducted on 10 (66.7%) patients after 6-25 months, no in-stent restenosis was detected.<br />Conclusion: Intra-aortic guiding catheter looping via transradial access for endovascular angioplasty of SISOLAs is technically safe, feasible, and effective, especially when the transfemoral artery approach is difficult or impossible to undertake.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2023 Xu, Xia, Cai, Yang, Zhao, Xue, Wang, Li and Gao.)

Details

Language :
English
ISSN :
1664-2295
Volume :
14
Database :
MEDLINE
Journal :
Frontiers in neurology
Publication Type :
Academic Journal
Accession number :
37900592
Full Text :
https://doi.org/10.3389/fneur.2023.1226306