Back to Search Start Over

Decontamination and Repair Protocol Promotes Positive Outcomes in Implants Affected by Peri-implantitis: A Human Case Series.

Authors :
Sallé MR
Deluiz D
Fletcher P
Santoro MF
Tinoco EMB
Source :
The International journal of periodontics & restorative dentistry [Int J Periodontics Restorative Dent] 2023 Nov 03; Vol. 43 (6), pp. 699-705.
Publication Year :
2023

Abstract

This study assessed the effectiveness and predictability of a readily available protocol to treat peri-implantitis utilizing mechanical debridement, chemical antiseptic surface detoxification, and osseous grafting. Nine patients (7 women, 2 men; mean age: 56.5 years) with 15 implants with peri-implantitis were included. Pocket probing depth (PPD), bleeding on probing (BOP), and standardized digital periapical radiographic measurements were taken. Surgical flaps were elevated, and the implant threads were cleaned with a plastic curette. Chemical decontamination was performed by scrubbing solutions of 0.25% sodium hypochlorite (NaClO) and 1.5% hydrogen peroxide (H2O2) around the exposed implant using cotton pellets. Bony defects were filled with a 50/50 mixture of bovine hydroxyapatite and nanocrystalline calcium sulfate (CaSO4). A porcine collagen membrane was placed over the grafted bony defect. Follow-up appointments were scheduled 1 week, 2 weeks, 3 months, 6 months, 9 months, and 1 year posttreatment. Clinical and radiographic parameters were assessed and compared. At baseline, PPD ranged from 5 to 7.5 mm (mean: 6 ± 0.7 mm). At 12 months, PPD ranged from 1.5 to 4.2 mm (mean: 2.5 ± 0.8 mm). The mean PPD reduction of 3.6 mm (59.2%) was statistically significant (P < .001). The number of bleeding sites around each test implant decreased significantly from 4 to 0.4 sites between baseline and 12 months (P < .001). Mean radiographic bone loss decreased from 4.8 ± 1.3 mm to 2.7 ± 1.2 mm (P < .001). The proposed method of mechanical decontamination, chemical detoxification, and bone regeneration is clinically effective and reproducible. Clinical peri-implant parameters and radiographic bone levels were improved and maintained their stability for 1 year using this peri-implantitis treatment protocol.

Details

Language :
English
ISSN :
1945-3388
Volume :
43
Issue :
6
Database :
MEDLINE
Journal :
The International journal of periodontics & restorative dentistry
Publication Type :
Academic Journal
Accession number :
37921607
Full Text :
https://doi.org/10.11607/prd.5534