Back to Search
Start Over
Characterizing complications associated with skull clamps: A review of the manufacturer and user facility device experience database.
- Source :
-
Clinical neurology and neurosurgery [Clin Neurol Neurosurg] 2023 Dec; Vol. 235, pp. 108043. Date of Electronic Publication: 2023 Nov 04. - Publication Year :
- 2023
-
Abstract
- Objective: Head immobilization with skull clamps is a prerequisite of many neurosurgical procedures. Adverse events relating to the use of skull clamps have been reported, however, given the paucity of published reports, we sought to conduct a more comprehensive analysis using the Manufacturer and User Facility Device Experience (MAUDE) database.<br />Methods: The MAUDE database was queried for neurosurgical skull clamp events over a 10-year period between January 2013 and December 2022. Reports were qualitatively analyzed and categorically assigned by the study authors as 'mechanical failure,' 'slippage,' 'contamination,' 'insufficient information,' and 'other.' Patient injury reports were also classified as 'abrasion,' 'laceration,' 'hematoma,' 'fracture,' 'intracranial hemorrhage (ICH),' 'other,' 'insufficient information,' and 'death.'<br />Results: Of 3672 reports retrieved, 2689 (73.2%) were device malfunctions, with mechanical failure (50.7%) and slippage (47.7%) being the most common causes. There were 983 reports (26.8%) involving patient injury which included lacerations (n = 776, 78.9%), fractures (n = 24, 2.4%), abrasions (n = 23, 2.3%), hematomas (n = 7, 0.71%), ICH (n = 3, 0.31%), and other causes (n = 6, 0.61%). Five (0.1%) deaths due to skull clamp related complications were also reported.<br />Conclusions: This study provides a more comprehensive picture of adverse events in neurosurgical procedures relating to the use of skull clamps. Mechanical failures of device parts were the most common device-related complication, and lacerations the most common adverse patient-related event. While more severe patient-related events were reported, they are relatively rare. The MAUDE database is useful for characterizing underreported device-related and patient-related adverse events.<br /> (Copyright © 2023 Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1872-6968
- Volume :
- 235
- Database :
- MEDLINE
- Journal :
- Clinical neurology and neurosurgery
- Publication Type :
- Academic Journal
- Accession number :
- 37944306
- Full Text :
- https://doi.org/10.1016/j.clineuro.2023.108043