A combination of non-invasive tests for the detection of significant fibrosis in patients with metabolic dysfunction-associated steatotic liver disease is not superior to magnetic resonance elastography alone.

Authors :
Duman S
Kuru D
Gumussoy M
Kiremitci S
Gokcan H
Ulas B
Ellik Z
Ozercan M
Er RE
Karakaya F
Bodakci E
Erden A
Elhan AH
Savas B
Loomba R
Idilman R
Source :
European radiology [Eur Radiol] 2024 Jun; Vol. 34 (6), pp. 3882-3888. Date of Electronic Publication: 2023 Nov 21.
Publication Year :
2024

Abstract

Objectives: The aims of the present study were to investigate a combination of magnetic resonance elastography (MRE) and vibration-controlled transient elastography (VCTE) or MRE and fibrosis score 4 (FIB-4) in the detection of significant fibrosis in patients with metabolic dysfunction-associated steatotic liver disease (MASLD).<br />Methods: Between November 5, 2021, and March 4, 2022, a total of 119 consecutive patients with MASLD were included. Liver stiffness was measured using liver biopsy, MRE, VCTE, and FIB-4. Data were collected from outpatient visit charts. Significant fibrosis was defined as ≥ stage 2 fibrosis.<br />Results: All 119 MASLD patients were Caucasian, and their median age was 55 years. MRE, VCTE, and FIB-4 demonstrated significant accuracy in the detection of significant fibrosis with an area under the ROC curve (AUC) of 0.848 ± 0.036 (p < 0.001), 0.632 ± 0.052 (p = 0.012), and 0.664 ± 0.051 (p = 0.001), respectively. However, the diagnostic performance of MRE was superior compared to that of VCTE (AUC difference: 0.216 ± 0.053, p < 0.001) and FIB-4 (AUC difference: 0.184 ± 0.058, p = 0.001). With logistic regression analysis, it was determined that when compared to MRE alone, a combination of MRE and TE (p = 0.880) or MRE and FIB-4 (p = 0.455) were not superior for detecting significant fibrosis.<br />Conclusions: MRE alone is an accurate and non-invasive method for the identification of MASLD patients with significant fibrosis.<br />Clinical Relevance Statement: Magnetic resonance elastography alone accurately detects significant fibrosis in patients with metabolic dysfunction-associated steatotic liver disease.<br />Key Points: • In routine clinical practice, several non-invasive biochemical-based biomarkers and imaging methods are widely used to assess liver fibrosis in patients with metabolic dysfunction-associated steatotic liver disease. • Magnetic resonance elastography (MRE) is more accurate than vibration-controlled transient elastography (VCTE) or fibrosis score 4 (FIB-4) for assessing liver fibrosis and identifying significant fibrosis in patients with metabolic dysfunction-associated steatotic liver disease. • The combination of MRE and VCTE or MRE and FIB-4 was not superior to MRE alone.<br /> (© 2023. The Author(s), under exclusive licence to European Society of Radiology.)

Details

Language :
English
ISSN :
1432-1084
Volume :
34
Issue :
6
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
37987833
Full Text :