Back to Search Start Over

Valvular and ascending aortic hemodynamics of the On-X aortic valved conduit by same-day echocardiography and 4D flow MRI.

Authors :
Lee J
Huh H
Scott MB
Elbaz MSM
Puthumana JJ
McCarthy P
Malaisrie SC
Markl M
Thomas JD
Barker AJ
Source :
Frontiers in cardiovascular medicine [Front Cardiovasc Med] 2023 Nov 14; Vol. 10, pp. 1256420. Date of Electronic Publication: 2023 Nov 14 (Print Publication: 2023).
Publication Year :
2023

Abstract

This study aims to assess whether the On-X aortic valved conduit better restores normal valvular and ascending aortic hemodynamics than other commonly used bileaflet mechanical valved conduit prostheses from St. Jude Medical and Carbomedics by using same-day transthoracic echocardiography (TTE) and 4D flow magnetic resonance imaging (MRI) examinations. TTE and 4D flow MRI were performed back-to-back in 10 patients with On-X, six patients with St. Jude (two) and Carbomedics (four) prostheses, and 36 healthy volunteers. TTE evaluated valvular hemodynamic parameters: transvalvular peak velocity (TPV), mean and peak transvalvular pressure gradient (TPG), and effective orifice area (EOA). 4D flow MRI evaluated the peak systolic 3D viscous energy loss rate (VELR) density and mean vorticity magnitude in the ascending aorta (AAo). While higher TPV and mean and peak TPG were recorded in all patients compared to healthy subjects, the values in On-X patients were closer to those in healthy subjects (TPV 1.9 ± 0.3 vs. 2.2 ± 0.3 vs. 1.2 ± 0.2 m/s, mean TPG 7.4 ± 1.9 vs. 9.2 ± 2.3 vs. 3.1 ± 0.9 mmHg, peak TPG 15.3 ± 5.2 vs. 18.9 ± 5.2 vs. 6.1 ± 1.8 mmHg, p  < 0.001). Likewise, while higher VELR density and mean vorticity magnitude were recorded in all patients than in healthy subjects, the values in On-X patients were closer to those in healthy subjects (VELR: 50.6 ± 20.1 vs. 89.8 ± 35.2 vs. 21.4 ± 9.2 W/m <superscript>3</superscript> , p  < 0.001) and vorticity (147.6 ± 30.0 vs. 191.2 ± 26.0 vs. 84.6 ± 20.5 s-1, p  < 0.001). This study demonstrates that the On-X aortic valved conduit may produce less aberrant hemodynamics in the AAo while maintaining similar valvular hemodynamics to St. Jude Medical and Carbomedics alternatives.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (© 2023 Lee, Huh, Scott, Elbaz, Puthumana, McCarthy, Malaisrie, Markl, Thomas and Barker.)

Details

Language :
English
ISSN :
2297-055X
Volume :
10
Database :
MEDLINE
Journal :
Frontiers in cardiovascular medicine
Publication Type :
Academic Journal
Accession number :
38034383
Full Text :
https://doi.org/10.3389/fcvm.2023.1256420