Back to Search Start Over

The GEM-handle as convenient labeling strategy for bimodal single-domain antibody-based tracers carrying 99m Tc and a near-infrared fluorescent dye for intra-operative decision-making.

Authors :
Declerck NB
Huygen C
Mateusiak L
Stroet MCM
Hernot S
Source :
Frontiers in immunology [Front Immunol] 2023 Nov 15; Vol. 14, pp. 1285923. Date of Electronic Publication: 2023 Nov 15 (Print Publication: 2023).
Publication Year :
2023

Abstract

Intra-operative fluorescence imaging has demonstrated its ability to improve tumor lesion identification. However, the limited tissue penetration of the fluorescent signals hinders the detection of deep-lying or occult lesions. Integrating fluorescence imaging with SPECT and/or intra-operative gamma-probing synergistically combines the deep tissue penetration of gamma rays for tumor localization with the precision of fluorescence imaging for precise tumor resection. In this study, we detail the use of a genetically encoded multifunctional handle, henceforth referred to as a GEM-handle, for the development of fluorescent/radioactive bimodal single-domain antibody (sdAb)-based tracers. A sdAb that targets the urokinase plasminogen activator receptor (uPAR) was engineered to carry a GEM-handle containing a carboxy-terminal hexahistidine-tag and cysteine-tag. A two-step labeling strategy was optimized and applied to site-specifically label IRDye800CW and <superscript>99m</superscript> Tc to the sdAb. Bimodal labeling of the sdAbs proved straightforward and successful. <superscript>99m</superscript> Tc activity was however restricted to 18.5 MBq per nmol fluorescently-labeled sdAb to prevent radiobleaching of IRDye800CW without impeding SPECT/CT imaging. Subsequently, the in vivo biodistribution and tumor-targeting capacity of the bimodal tracer were evaluated in uPAR-positive tumor-bearing mice using SPECT/CT and fluorescence imaging. The bimodal sdAb showed expected renal background signals due to tracer clearance, along with slightly elevated non-specific liver signals. Four hours post-injection, both SPECT/CT and fluorescent images achieved satisfactory tumor uptake and contrast, with significantly higher values observed for the anti-uPAR bimodal sdAb compared to a control non-targeting sdAb. In conclusion, the GEM-handle is a convenient method for designing and producing bimodal sdAb-based tracers with adequate in vivo characteristics.<br />Competing Interests: LM and SH acknowledge that they hold a patent for ‘Anti-urokinase plasminogen activator receptor immunoglobulin single variable domains’, under EP22199885.9. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2023 Declerck, Huygen, Mateusiak, Stroet and Hernot.)

Details

Language :
English
ISSN :
1664-3224
Volume :
14
Database :
MEDLINE
Journal :
Frontiers in immunology
Publication Type :
Academic Journal
Accession number :
38035094
Full Text :
https://doi.org/10.3389/fimmu.2023.1285923