Back to Search Start Over

Percutaneous coronary intervention with ridaforolimus eluting-stents in small vessel coronary artery disease.

Authors :
Arow Z
Konigstein M
Vaknin-Assa H
Witberg G
Jonas M
Kerner A
Cafri C
Rubinshtein R
Segev A
Roguin A
Issever MO
Gabarin M
Pereg D
Assali A
Koifman E
Source :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2024 Jan; Vol. 103 (1), pp. 61-67. Date of Electronic Publication: 2023 Dec 14.
Publication Year :
2024

Abstract

Introduction: The ridaforolimus-eluting stent (RES) system uses a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting ridaforolimus.<br />Aim of Study: To assess the safety and efficacy of small diameter (2.25 mm) RES (EluNIR) in small coronary artery disease.<br />Methods: A prospective, multicenter, single-arm, open-label clinical trial. Clinical follow-up was performed at 30 days, 6 months, and 1 year after the procedure. Target lesions were located in native coronary arteries or bypass graft conduits, with visually estimated diameter of ≥2.25 mm to ≤2.5 mm. The primary endpoint was combined device success, defined as final in-stent residual diameter stenosis <30%, without 30-day major adverse cardiovascular events (MACE).<br />Results: A total of 81 patients were enrolled in the study. Twenty-three patients (28%) had acute coronary syndrome (ACS) at presentation and 37 (46%) had prior myocardial infarction (MI). Most of the target lesions were located in the circumflex coronary artery (44%) and were classified as B2/C grade according to the American Heart Association/American College of Cardiology classification. The final mean minimal lumen diameter, mean reference vessel diameter, and mean residual percent diameter stenosis were 2.0 ± 0.2 mm, 2.3 ± 0.1 mm, and 14 + 6.6%, respectively. The primary endpoint of device success without 30-day MACE was achieved in 98.8% of the patients. Target lesion failure (TLF) at 6 months was 1.2%. Thirty-day and 1-year MACE rates were 1.2% and 2.5%, respectively.<br />Conclusion: The EluNIR 2.25 mm stent shows excellent results in small coronary artery disease and adds another tool in the treatment of this complex lesion type.<br /> (© 2023 The Authors. Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1522-726X
Volume :
103
Issue :
1
Database :
MEDLINE
Journal :
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
Publication Type :
Academic Journal
Accession number :
38098249
Full Text :
https://doi.org/10.1002/ccd.30924