Implantable cardioverter defibrillator and cardiac resynchronization treatment in people with type 2 diabetes: a comparison with age- and sex matched controls from the general population.

Authors :
Rautio E
Gadler F
Gudbjörnsdottir S
Franzén S
Rydén L
Savarese G
Svensson AM
Mellbin LG
Source :
Cardiovascular diabetology [Cardiovasc Diabetol] 2024 Jan 06; Vol. 23 (1), pp. 18. Date of Electronic Publication: 2024 Jan 06.
Publication Year :
2024

Abstract

Background: Increased risk of severe tachyarrhythmias is reported in patients with type 2 diabetes mellitus (T2DM). The aim of this study was to explore if treatment with cardiac implantable electronic device (CIED) such as implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy- pacemaker and -defibrillator (CRT-P/CRT-D) differed in patients with vs. without T2DM. A secondary aim was to identify patient characteristics indicating an increased CIED treatment.<br />Method: 416 162 adult patients with T2DM from the Swedish National Diabetes Registry and 2 081 087 controls from the Swedish population, matched for age, sex and living area, were included between 1/1/1998 and 31/12/2012 and followed until 31/12/2013. They were compared regarding prevalence of ventricular tachycardia (VT) at baseline and the risk of receiving a CIED during follow-up. Multivariable Cox regression analysis was performed to estimate the risk of CIED-treatment and factors identifying patients with such risk.<br />Results: Ventricular fibrillation (VF) (0.1% vs 0.0004%) and (VT) (0.2% vs. 0.1%) were more frequent among patients with T2DM compared to controls. CIED-treatment was significantly increased in patients with T2DM both in unadjusted and adjusted analyses. HR and 95% CI, after adjustment for sex, age, marital status, income, education, country of birth, coronary artery disease and congestive heart failure, were 1.32 [1.21-1.45] for ICD, 1.74 [1.55-1.95] for CRT-P and 1.69 [1.43-1.99] for CRT-D. Blood-pressure and lipid lowering therapies were independent risk factors associated to receiving CIED, while female sex was protective.<br />Conclusions: Although the proportion of VT/VF was low, patients with T2DM had a higher prevalence of these conditions and increased risk for treatment with CIED compared to controls. This underlines the importance of recognizing that T2DM patients have an increased need of CIED.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
1475-2840
Volume :
23
Issue :
1
Database :
MEDLINE
Journal :
Cardiovascular diabetology
Publication Type :
Academic Journal
Accession number :
38184588
Full Text :
https://doi.org/10.1186/s12933-023-02084-z