Back to Search
Start Over
Usefulness of the spectral shaping dual-source computed tomography imaging technique in posterior corrective fusion for adolescent idiopathic scoliosis.
- Source :
-
European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society [Eur Spine J] 2024 Feb; Vol. 33 (2), pp. 706-712. Date of Electronic Publication: 2024 Jan 17. - Publication Year :
- 2024
-
Abstract
- Purpose: Since childhood exposure to radiation has been demonstrated to increase cancer risk with increase in radiation dose, reduced radiation exposure during computed tomography (CT) evaluation is desired for adolescent idiopathic scoliosis (AIS). Therefore, this retrospective study aimed to investigate the radiation dose of dual-source CT using a spectral shaping technique and the accuracy of the thoracic pedicle screw (TPS) placement for posterior spinal fusion (PSF) in patients with AIS.<br />Methods: Fifty-nine female patients with thoracic AIS who underwent PSF using CT-guided TPSs were included and divided into two groups comprised of 23 patients who underwent dual-source CT (DSCT) with a tin filter (DSCT group) and 36 who underwent conventional multislice CT (MSCT group). We assessed the CT radiation dose using the CT dose index (CTDI <subscript>vol</subscript> ), effective dose (ED), and accuracy of TPS insertion according to the established Neo's classification.<br />Results: The DSCT and MSCT groups differed significantly (p < 0.001) in the mean CTDI <subscript>vol</subscript> (0.76 vs. 3.31 mGy, respectively) and ED (0.77 vs. 3.47 mSv, respectively). Although the correction rate of the main thoracic curve in the DSCT group was lower (65.7% vs. 71.2%) (p = 0.0126), the TPS accuracy (Grades 0-1) was similar in both groups (381 screws [88.8%] vs. 600 screws [88.4%], respectively) (p = 0.8133). No patient required replacement of malpositioned screws.<br />Conclusion: Spectral shaping DSCT with a tube-based tin filter allowed a 75% radiation dose reduction while achieving TPS insertion accuracy similar to procedures based on conventional CT without spectral shaping.<br /> (© 2024. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.)
Details
- Language :
- English
- ISSN :
- 1432-0932
- Volume :
- 33
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society
- Publication Type :
- Academic Journal
- Accession number :
- 38233628
- Full Text :
- https://doi.org/10.1007/s00586-023-08006-7