Back to Search
Start Over
External Validation of the Effect of the Combined Use of Object Detection for the Classification of the C-Shaped Canal Configuration of the Mandibular Second Molar in Panoramic Radiographs: A Multicenter Study.
- Source :
-
Journal of endodontics [J Endod] 2024 May; Vol. 50 (5), pp. 627-636. Date of Electronic Publication: 2024 Feb 08. - Publication Year :
- 2024
-
Abstract
- Introduction: The purposes of this study were to evaluate the effect of the combined use of object detection for the classification of the C-shaped canal anatomy of the mandibular second molar in panoramic radiographs and to perform an external validation on a multicenter dataset.<br />Methods: The panoramic radiographs of 805 patients were collected from 4 institutes across two countries. The CBCT data of the same patients were used as "Ground-truth". Five datasets were generated: one for training and validation, and 4 as external validation datasets. Workflow 1 used manual cropping to prepare the image patches of mandibular second molars, and then classification was performed using EfficientNet. Workflow 2 used two combined methods with a preceding object detection (YOLOv7) performed for automated image patch formation, followed by classification using EfficientNet. Workflow 3 directly classified the root canal anatomy from the panoramic radiographs using the YOLOv7 prediction outcomes. The classification performance of the 3 workflows was evaluated and compared across 4 external validation datasets.<br />Results: For Workflows 1, 2, and 3, the area under the receiver operating characteristic curve (AUC) values were 0.863, 0.861, and 0.876, respectively, for the AGU dataset; 0.935, 0.945, and 0.863, respectively, for the ASU dataset; 0.854, 0.857, and 0.849, respectively, for the ODU dataset; and 0.821, 0.797, and 0.831, respectively, for the ODU low-resolution dataset. No significant differences existed between the AUC values of Workflows 1, 2, and 3 across the 4 datasets.<br />Conclusions: The deep learning systems of the 3 workflows achieved significant accuracy in predicting the C-shaped canal in mandibular second molars across all test datasets.<br /> (Copyright © 2024 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1878-3554
- Volume :
- 50
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Journal of endodontics
- Publication Type :
- Academic Journal
- Accession number :
- 38336338
- Full Text :
- https://doi.org/10.1016/j.joen.2024.01.022