Back to Search Start Over

Facial electromyography during exercise using soft electrode array: A feasibility study.

Authors :
Ibrahim R
Ketko I
Scheinowitz M
Hanein Y
Source :
PloS one [PLoS One] 2024 Feb 15; Vol. 19 (2), pp. e0298304. Date of Electronic Publication: 2024 Feb 15 (Print Publication: 2024).
Publication Year :
2024

Abstract

The use of wearable sensors for real-time monitoring of exercise-related measures has been extensively studied in recent years (e.g., performance enhancement, optimizing athlete's training, and preventing injuries). Surface electromyography (sEMG), which measures muscle activity, is a widely researched technology in exercise monitoring. However, due to their cumbersome nature, traditional sEMG electrodes are limited. In particular, facial EMG (fEMG) studies in physical training have been limited, with some scarce evidence suggesting that fEMG may be used to monitor exercise-related measurements. Altogether, sEMG recordings from facial muscles in the context of exercise have been examined relatively inadequately. In this feasibility study, we assessed the ability of a new wearable sEMG technology to measure facial muscle activity during exercise. Six young, healthy, and recreationally active participants (5 females), performed an incremental cycling exercise test until exhaustion, while facial sEMG and vastus lateralis (VL) EMG were measured. Facial sEMG signals from both natural expressions and voluntary smiles were successfully recorded. Stable recordings and high-resolution facial muscle activity mapping were achieved during different exercise intensities until exhaustion. Strong correlations were found between VL and multiple facial muscles' activity during voluntary smiles during exercise, with statistically significant coefficients ranging from 0.80 to 0.95 (p<0.05). This study demonstrates the feasibility of monitoring facial muscle activity during exercise, with potential implications for sports medicine and exercise physiology, particularly in monitoring exercise intensity and fatigue.<br />Competing Interests: YH declares a financial interest in X-trodes Ltd, which developed the screen-printed electrode technology used in this paper. YH has no other relevant financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript apart from those disclosed. This does not alter our adherence to PLOS ONE policies on sharing data and materials.<br /> (Copyright: © 2024 Ibrahim et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
19
Issue :
2
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
38358981
Full Text :
https://doi.org/10.1371/journal.pone.0298304