Back to Search Start Over

Impact of Left Atrial Posterior Wall Ablation During Pulsed-Field Ablation for Persistent Atrial Fibrillation.

Authors :
Turagam MK
Neuzil P
Schmidt B
Reichlin T
Neven K
Metzner A
Hansen J
Blaauw Y
Maury P
Arentz T
Sommer P
Anic A
Anselme F
Boveda S
Deneke T
Willems S
van der Voort P
Tilz R
Funasako M
Scherr D
Wakili R
Steven D
Kautzner J
Vijgen J
Jais P
Petru J
Chun J
Roten L
Füting A
Lemoine MD
Ruwald M
Mulder BA
Rollin A
Lehrmann H
Fink T
Jurisic Z
Chaumont C
Adelino R
Nentwich K
Gunawardene M
Ouss A
Heeger CH
Manninger M
Bohnen JE
Sultan A
Peichl P
Koopman P
Derval N
Kueffer T
Reinsch N
Reddy VY
Source :
JACC. Clinical electrophysiology [JACC Clin Electrophysiol] 2024 May; Vol. 10 (5), pp. 900-912. Date of Electronic Publication: 2024 Jan 31.
Publication Year :
2024

Abstract

Background: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury.<br />Objectives: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA).<br />Methods: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events.<br />Results: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA <subscript>2</subscript> DS <subscript>2</subscript> -VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51).<br />Conclusions: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.<br />Competing Interests: Funding Support and Author Disclosures Boston Scientific provided a grant to help fund data collection but was not otherwise involved with study design or analysis nor did they have access to this manuscript before submission. Dr Turagam has received consulting fees from Biosense Webster; and has received speaker honorarium from Sanofi and Medtronic. Dr Neuzil has received grants from the Ministry of Health, Czech Republic, DRO (NHH, 00023884). Dr Schmidt has received speaker fees and research grants from Boston Scientific/Farapulse, Medtronic, Biosense Webster, and Abbott. Dr Reichlin has received grants from the Swiss National Science Foundation, the Swiss Heart Foundation, and the sitem insel support fund; has received speaker/consulting honoraria or travel support from Abbott/SJM, Bayer, Biosense Webster, Biotronik, Boston Scientific, Daiichi Sankyo, Medtronic, and Pfizer-BMS; and has received support for his institution’s fellowship program from Abbott/SJM, Biosense Webster, Biotronik, Boston Scientific, and Medtronic. Dr Metzner has received grants and fees from Farapulse. Dr Hansen has received speaker fees and grant support from Biosense Webster and Medtronic. Dr Blaauw has received grants from Medtronic and Atricure; and has received consulting fees from Abbott, Biosense Webster, and Boston Scientific. Dr Sommer has been a member of the advisory boards for Abbott, Biosense Webster, Boston Scientific, and Medtronic. Dr Anic has received consultant fees from Farapulse Inc, Boston Scientific Inc, Galaxy Medical Inc, Biosense Webster; and has performed contracted research for Farapulse Inc, Boston Scientific Inc, Galaxy Medical Inc, and Biosense Webster. Dr Anselme has received consulting fees from Boston Scientific, Medtronic, and Microport CRM. Dr Boveda has received consulting fees from Medtronic, Boston Scientific, Microport, Zoll, and BMS. Dr Deneke has received speaker honoraria from Galaxy Medical, Abbott, and Biotronik; has received consulting fees from Farapulse; and has served on a Clinical Events Committee for Boston Scientific. Dr Willems has received grants and personal fees from Abbott, Boston Scientific, and Medtronic; and has received personal fees from Boehringer Ingelheim, Brystol Myers Squibb, Bayer Vital, Accutus, Daiichi, and Farapulse Inc. Dr Tilz reports receiving consulting fees from Boston Scientific, Abbott Medical, Biotronik, Biosense Webster and speaker honorarium from Boston Scientific, Abbott Medical, Biotronik, Biosense Webster. Dr Scherr has received an educational grant from Farapulse Inc; and is a consultant For Boston Scientific Inc. Dr Wakili has received consulting fees and travel expenses from Boston Scientific and Biotronik; has received investigator-initiated funding for research projects (initiated by him) from Bristol-Myers Squibb, Pfizer, and Boston Scientific; and has received speaking honoraria from Boston Scientific, Biotronik, and Medtronic. Dr Scherr has received speaking fees from Pfizer, Bayer, Abbott, Johnson & Johnson, and Medtronic; has received grants from Abbott, Johnson & Johnson, and Boston Scientific; and has received consulting fees from Boston Scientific and Johnson & Johnson. Dr Kautzner has received personal fees from Bayer, Biosense Webster, Boehringer Ingelheim, Medtronic, and Abbott for participation in scientific advisory boards; and has received speaker honoraria from Bayer, Biosense Webster, Biotronik, Boehringer Ingelheim, CathVision, Medtronic, Mylan, Pfizer, ProMed, and Abbott. Dr Jais has received partial funding from IHU LIRYC ANR-10-IAHU-04; has received equity from Farapulse; and has received consulting fees and grants from Boston Scientific. Dr Chun has received speaker fees and research grants from Boston Scientific/Farapulse, Medtronic, Biosense Webster, and Abbott. Dr Roten has received speaker honoraria from Abbott/SJM; has received consulting honoraria from Medtronic; and has received research funding to the institution from Medtronic. Dr Lemoine has received grants from Farapulse. Dr Rollin has received grants from Farapulse. Dr Nentwich has received speaker fees from Farapulse, Inc. Dr Gunawardine has received grants from Farapulse Inc and Abbott. Dr Heeger has received travel grants and research grants from Boston Scientific, Lifetech, Biosense Webster, and Cardiofocus; has received speaker honoraria from Boston Scientific, Lifetech, Biosense Webster, Bayer, and Cardiofocus; and has received consulting fees from Medtronic, Lifetech, Boston Scientific, Biosense Webster, and Cardiofocus. Dr Manninger has received speaker fees from Bayer, Biosense Webster, Biotronik, Amomed, AOP Orphan, Boston Scientific, Daiichi Sankyo, and BMS/Pfizer; and has received grants from Biosense Webster and Abbott. Dr Sultan has received lecture and consulting honoraria from Medtronic, Abbott, and Bayer. Dr Derval has received consulting fees from Boston Scientific. Dr Reddy has received consulting fees (and equity – now divested) from Farapulse Inc; has received consulting fees from Boston Scientific Inc; and, unrelated to this manuscript, has served as a consultant for and has equity in Ablacon, Acutus Medical, Affera-Medtronic, Apama Medical-Boston Scientific, Anumana, APN Health, Aquaheart, Atacor, Autonomix, Axon Therapies, Backbeat, BioSig, CardiaCare, CardioNXT/AFTx, Circa Scientific, CoRISMA, Corvia Medical, Dinova-Hangzhou DiNovA EP Technology, East End Medical, EPD-Philips, EP Frontiers, Epix Therapeutics-Medtronic, EpiEP, Eximo, Field Medical, Focused Therapeutics, HRT, Intershunt, Javelin, Kardium, Keystone Heart, Laminar, LuxMed, Medlumics, Middlepeak, Neutrace, Nuvera-Biosense Webster, Oracle Health, Restore Medical, Sirona Medical, SoundCath, Valcare; also unrelated to this work, he has received consulting fees from AtriAN, Biosense-Webster, BioTel Heart, Biotronik, Cairdac, Cardiofocus, Cardionomic, CoreMap, Fire1, Gore & Associates, Impulse Dynamics, Medtronic, Novartis, Philips, and Pulse Biosciences; and he has equity in Manual Surgical Sciences, Newpace, Nyra Medical, Surecor, and Vizaramed. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.<br /> (Copyright © 2024 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.)