Concordance Analysis of the Pressure Chamber and Tubomanometer According to Estève for the Determination of Eustachian Tube Opening Pressure.

Authors :
Deuss E
Löding K
Breitrück N
Lang S
Klußmann JP
Jansen S
Meyer MF
Source :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology [Otol Neurotol] 2024 Jun 01; Vol. 45 (5), pp. e411-e419. Date of Electronic Publication: 2024 Mar 21.
Publication Year :
2024

Abstract

Introduction: For the diagnosis of Eustachian tube dysfunction (ETD), clinical procedures such as tympanometry, micro-otoscopy, and maneuvers according to Toynbee and Valsalva only allow an indirect assessment for the moment. With a prevalence of up to 5%, the selection of patients with ETD and its subtypes is clinically relevant. Dynamic methods of Eustachian tube function assessment include a hypo/hyperbaric pressure chamber and Estève's tubomanometer (TMM). One method of assessing ETD is the evaluation of Eustachian tube opening pressure (ETOP).<br />Material and Methods: We performed a concordance analysis between pressure chamber and TMM to determine ETOP. For this purpose, we analyzed the measurements of both methods from 28 healthy subjects using Bland-Altman plots, regression according to Passing-Bablok and Lin's concordance correlations coefficient. The maximum tolerated clinical deviation of measured values was set at 10%.<br />Results: A maximum of 53 measurements of ETOP between pressure chamber and TMM were compared. Mean ETOP for TMM was 28.7 hPa, passive opening was 32 hPa, Toynbee maneuver was 28.4 hPa, and Valsalva maneuver was 54.6 hPa. Concordance analysis revealed following results: passive opening versus TMM: Bland-Altman mean difference 3.3 hPa, limits of agreement ±31.8 hPa; Passing-Bablok regression y = 0.67 x + 9.36; Lin's rccc = 0.18. Toynbee versus TMM: Bland-Altman mean difference 0.7 hPa, limits of agreement ±35.8 hPa; Passing-Bablok regression y = 0.47x + 14.03; Lin's rccc = 0.14. Valsalva versus TMM: Bland-Altman mean difference 24.2 hPa, limits of agreement ±117.5 hPa; Passing-Bablok regression y = 0.17x + 25.12; Lin's rccc = 0.18.<br />Conclusion: Estève's tubomanometer and pressure chamber measurements of ETOP are not concordant. The two methods cannot be interchanged without reservation.<br />Competing Interests: Conflicts of interest: The authors declare no conflicts of interest.<br /> (Copyright © 2024, Otology & Neurotology, Inc.)

Details

Language :
English
ISSN :
1537-4505
Volume :
45
Issue :
5
Database :
MEDLINE
Journal :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
Publication Type :
Academic Journal
Accession number :
38509803
Full Text :
https://doi.org/10.1097/MAO.0000000000004171