Investigation on the Validity of in vitro Sun Protection Factor and Ultraviolet-A Protection Factor Evaluation Method for Sunscreen Samples.
- Source :
-
Journal of oleo science [J Oleo Sci] 2024; Vol. 73 (4), pp. 603-610. - Publication Year :
- 2024
-
Abstract
- Factors affecting the in vitro Sun Protection Factor (SPF) and Ultraviolet-A Protection Factor (UVA-PF) of sunscreens were analyzed for verifying the validity and reliability of the ISO24443 evaluation method. UV absorbance measurements by different spectrophotometers did not lead to the large difference in in vitro SPF/UVA-PF, although the UV absorbance determined by each spectrophotometer exhibited relatively large difference when it was larger than 2. On the other hand, relatively large difference was found in in vitro SPF/UVA-PF by utilizing European Cosmetic and Perfumery Association (Colipa) 1994 or UV-solar simulated radiation (UV-SSR) for the spectral irradiance. Appropriateness of employing the coefficient of adjustment for the determination of in vitro UVA-PF was also found to be reexamined.