Back to Search Start Over

Management of aortic valve insufficiency in patients with continuous-flow left ventricular assist device: a republication of the review published in Japanese Journal of Artificial Organs.

Authors :
Tadokoro N
Tonai K
Kainuma S
Kawamoto N
Suzuki K
Hirayama M
Fukushima S
Source :
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs [J Artif Organs] 2024 Sep; Vol. 27 (3), pp. 177-181. Date of Electronic Publication: 2024 Apr 10.
Publication Year :
2024

Abstract

Since 2011, implantable ventricular assist devices have been a standard treatment for severe heart failure alongside heart transplantation in Japan. However, the limited availability of donors has led to a prolonged wait for transplants, now averaging 1719 days, intensifying the issue of aortic insufficiency in patients with continuous flow ventricular assist devices. These devices limit the opening of the aortic valve, leading to sustained closure and increased shear stress, which accelerates valve degradation. Risk factors for aortic insufficiency include having a smaller body surface area, being of advanced age, and the presence of mild aortic insufficiency prior to device implantation. In patients presenting with mild or moderate aortic regurgitation at the time of ventricular assist device implantation, interventions such as aortic valve repair or bioprosthetic valve replacement are performed with the aim of halting its progression. The choice of surgical procedure should be tailored to each patient's individual condition. The management of de novo aortic insufficiency in patients with continuous flow ventricular assist devices remains challenging, with no clear consensus on when to intervene. Interventions for significant aortic insufficiency typically consider the patient's symptoms and aortic insufficiency severity. De novo aortic insufficiency progression in continuous flow ventricular assist devices patients necessitates careful monitoring and intervention based on individual patient assessments and valve condition. This review was created based on a translation of the Japanese review written in the Japanese Journal of Artificial Organs in 2023 (Vol. 52, No. 1, pp. 77-80), with some modifications.<br /> (© 2024. The Japanese Society for Artificial Organs.)

Details

Language :
English
ISSN :
1619-0904
Volume :
27
Issue :
3
Database :
MEDLINE
Journal :
Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs
Publication Type :
Academic Journal
Accession number :
38594483
Full Text :
https://doi.org/10.1007/s10047-024-01439-x