Back to Search Start Over

Using Patient-Specific Contrast Enhancement Optimizer Simulation Software During the Transcatheter Aortic Valve Implantation-Computed Tomography Angiography in Patients With Aortic Stenosis.

Authors :
Masuda T
Nakaura T
Higaki T
Funama Y
Matsumoto Y
Sato T
Okimoto T
Arao K
Imaizumi H
Arao S
Ono A
Hiratsuka J
Awai K
Source :
Journal of computer assisted tomography [J Comput Assist Tomogr] 2024 Sep-Oct 01; Vol. 48 (5), pp. 759-762. Date of Electronic Publication: 2024 Apr 08.
Publication Year :
2024

Abstract

Objectives: This study assessed whether patient-specific contrast enhancement optimizer simulation software (p-COP) can reduce the contrast material (CM) dose compared with the conventional body weight (BW)-tailored scan protocol during transcatheter aortic valve implantation-computed tomography angiography (TAVI-CTA) in patients with aortic stenosis.<br />Methods: We used the CM injection protocol selected by the p-COP in group A (n = 30). p-COP uses an algorithm that concerns data on an individual patient's cardiac output. Group B (n = 30) was assigned to the conventional BW-tailored CM injection protocol group. We compared the CM dose, CM amount, injection rate, and computed tomography (CT) values in the abdominal aorta between the 2 groups and classified them as acceptable (>280 Hounsfield units (HU)) or unacceptable (<279 HU) based on the optimal CT value and visualization scores for TAVI-CTA. We used the Mann-Whitney U test to compare patient characteristics and assess the interpatient variability of subjects in both groups.<br />Results: Group A received 56.2 mL CM and 2.6 mL/s of injection, whereas group B received 76.9 mL CM and 3.4 mL/s of injection ( P < 0.01). The CT value for the abdominal aorta at the celiac level was 287.0 HU in group A and 301.7HU in group B ( P = 0.46). The acceptable (>280 HU) and unacceptable (<280 HU) CT value rates were 22 and 8 patients in group A and 24 and 6 patients in group B, respectively ( P = 0.76). We observed no significant differences in the visualization scores between groups A and B (visualization score = 3, P = 0.71).<br />Conclusion: The utilization of p-COP may decrease the CM dosage and injection rate by approximately 30% in individuals with aortic stenosis compared with the body-weight-tailored scan protocol during TAVI-CTA.<br /> (Copyright © 2024 Wolters Kluwer Health, Inc. All rights reserved.)

Details

Language :
English
ISSN :
1532-3145
Volume :
48
Issue :
5
Database :
MEDLINE
Journal :
Journal of computer assisted tomography
Publication Type :
Academic Journal
Accession number :
38595080
Full Text :
https://doi.org/10.1097/RCT.0000000000001603