Back to Search Start Over

Comparison of quality and interpretation of newborn ultrasound screening examinations for developmental dysplasia of the hip by basically trained nurses and junior physicians with no previous ultrasound experience.

Authors :
Ulziibat M
Munkhuu B
Schmid R
Wyder C
Baumann T
Essig S
Source :
PloS one [PLoS One] 2024 Apr 18; Vol. 19 (4), pp. e0300753. Date of Electronic Publication: 2024 Apr 18 (Print Publication: 2024).
Publication Year :
2024

Abstract

Background: We are obliged to give babies the chance to profit from a nationwide screening of developmental dysplasia of the hip in very rural areas of Mongolia, where trained physicians are scarce. This study aimed to compare the quality and interpretation of hip ultrasound screening examinations performed by nurses and junior physicians.<br />Methods: A group of 6 nurses and 6 junior physician volunteers with no previous ultrasound experience underwent Graf's standard training in hands-on practice. Newborns were examined before discharge from the hospital, according to the national guideline. Two standard documentation images of each hip were saved digitally. The groups were compared on the proportion of good quality of sonograms and correct interpretation. Two Swiss supervisors' agreed diagnosis according to Graf was considered the final reference for the study purposes.<br />Results: A total of 201 newborns (402 hips or 804 sonograms) were examined in the study, with a mean age of 1.3±0.8 days at examination. Junior physicians examined 100 newborns (200 hips or 400 sonograms), while nurses examined 101 newborns (202 hips or 404 sonograms). The study subjects of the two groups were well balanced for the distribution of baseline characteristics. The study observed no statistically significant difference in the quality of Graf's standard plane images between the providers. Eventually, 92.0% (92) of the physician group and 89.1% (90) of the nurse group were correctly diagnosed as "Group A" (Graf's Type 1 hip) or "Non-Group A" hips (p = 0.484). The most common errors among the groups were a missing lower limb, wrong measurement lines, and technical problems.<br />Conclusion: Our study provides evidence that while there might be a trend of slightly more technical mistakes in the nurse group, the overall diagnosis accuracy is similar to junior physicians after receiving standard training in Graf's hip ultrasound method. However, after basic training, regular quality control is a must and all participants should receive refresher trainings. More specifically, nurses need training in the identification of anatomical structures.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2024 Ulziibat et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
19
Issue :
4
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
38635681
Full Text :
https://doi.org/10.1371/journal.pone.0300753