Back to Search
Start Over
Nexplanonectomy-the surgical removal of an embolized implanted contraceptive device: a case report and review of the literature.
- Source :
-
Journal of medical case reports [J Med Case Rep] 2024 May 02; Vol. 18 (1), pp. 234. Date of Electronic Publication: 2024 May 02. - Publication Year :
- 2024
-
Abstract
- Background: Nexplanon implants are a common hormonal contraceptive modality. Though rare, these devices can embolize into the injured wall of the basilic vein, through the right heart, and finally wedge itself into a pulmonary artery. With adherence to the arterial wall over time, it becomes less amenable to endovascular retrieval. Patients may present with symptoms mimicking a pulmonary embolism, or without any symptoms at all. In asymptomatic cases, endovascular retrieval and/or surgery is required when patients wish to begin having children prior to biological inactivity. The current literature showed as little as nine case reports detailing lung tissue removal in the aim of reversing a patient's implanted contraceptive device.<br />Case Presentation: A 22-year-old asymptomatic active-duty Caucasian female presented for elective outpatient Nexplanon removal. The suspicion of possible implant migration arose when it was discovered to be non-palpable in her left arm. After plain film x-rays failed to localize the implant, a chest x-ray and follow-up Computed Tomography (CT) scan revealed that the Nexplanon had migrated to a distal branch of the left pulmonary artery. Due to the patient's strong desires to begin having children, the decision was made for removal. Initial endovascular retrieval failed due to Nexplanon encapsulation within the arterial wall. Ultimately, the patient underwent a left video-assisted thoracoscopic surgery (VATS) for exploration and left lower lobe basilar S7-9 segmentectomy, which successfully removed the Nexplanon.<br />Conclusions: Implanted contraceptive devices can rarely result in migration to the pulmonary vasculature. These radiopaque devices are detectable on imaging studies if patients and clinicians are unable to palpate them. An endovascular approach should be considered first to spare lung tissue and avoid chest-wall incisions, but can be complicated by encapsulation and adherence to adjacent tissue. A VATS procedure with single-lung ventilation via a double-lumen endotracheal tube allows surgeons to safely operate on an immobilized lung while anesthesiologists facilitate single-lung ventilation. This patient's case details the uncommon phenomenon of Nexplanon migration, and the exceedingly rare treatment resolution of lung resection to remove an embolized device.<br /> (© 2024. This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply.)
- Subjects :
- Humans
Female
Young Adult
Contraceptive Agents, Female administration & dosage
Drug Implants
Pulmonary Artery surgery
Pulmonary Artery diagnostic imaging
Tomography, X-Ray Computed
Pulmonary Embolism etiology
Treatment Outcome
Pneumonectomy
Device Removal methods
Desogestrel administration & dosage
Foreign-Body Migration surgery
Foreign-Body Migration diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1752-1947
- Volume :
- 18
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of medical case reports
- Publication Type :
- Academic Journal
- Accession number :
- 38698425
- Full Text :
- https://doi.org/10.1186/s13256-024-04547-7