Back to Search Start Over

Revolutionizing Glucose Monitoring: Enzyme-Free 2D-MoS 2 Nanostructures for Ultra-Sensitive Glucose Sensors with Real-Time Health-Monitoring Capabilities.

Authors :
Bano M
Naikoo GA
BaOmar F
Rather JA
Hassan IU
Sheikh RA
Kannan P
Tambuwala MM
Source :
ACS omega [ACS Omega] 2024 Apr 25; Vol. 9 (18), pp. 20021-20029. Date of Electronic Publication: 2024 Apr 25 (Print Publication: 2024).
Publication Year :
2024

Abstract

The growing requirement for real-time monitoring of health factors such as heart rate, temperature, and blood glucose levels has resulted in an increase in demand for electrochemical sensors. This study focuses on enzyme-free glucose sensors based on 2D-MoS <subscript>2</subscript> nanostructures explored by simple hydrothermal route. The 2D-MoS <subscript>2</subscript> nanostructures were characterized by powder X-ray diffraction, energy-dispersive X-ray spectroscopy, scanning electron microscopy, transmission electron microscopy, Raman spectroscopy, and XPS techniques and were immobilized at GCE to obtain MoS <subscript>2</subscript> -GCE interface. The fabricated interface was characterized by electrochemical impedance spectroscopy which shows less charge transfer resistance and demonstrated superior electrocatalytic properties of the modified surface. The sensing interface was applied for the detection of glucose using amperometry. The MoS <subscript>2</subscript> -GCE-sensing interface responded effectively as a nonenzymatic glucose sensor (NEGS) over a linearity range of 0.01-0.20 μM with a very low detection limit of 22.08 ng mL <superscript>-1</superscript> . This study demonstrates an easy method for developing a MoS <subscript>2</subscript> -GCE interface, providing a potential option for the construction of flexible and disposable nonenzymatic glucose sensors (NEGS). Moreover, the fabricated MoS <subscript>2</subscript> -GCE electrode precisely detected glucose molecules in real blood serum and urine samples of diabetic and nondiabetic persons. These findings suggest that 2D-MoS <subscript>2</subscript> nanostructured materials show considerable promise as a possible option for hyperglycemia detection and therapy. Furthermore, the development of NEGS might create new prospects in the glucometer industry.<br />Competing Interests: The authors declare no competing financial interest.<br /> (© 2024 The Authors. Published by American Chemical Society.)

Details

Language :
English
ISSN :
2470-1343
Volume :
9
Issue :
18
Database :
MEDLINE
Journal :
ACS omega
Publication Type :
Academic Journal
Accession number :
38737026
Full Text :
https://doi.org/10.1021/acsomega.3c10117