Back to Search
Start Over
Three-dimensional CT reconstruction-guided percutaneous balloon compression for trigeminal neuralgia.
- Source :
-
Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia [J Clin Neurosci] 2024 Jul; Vol. 125, pp. 120-125. Date of Electronic Publication: 2024 May 20. - Publication Year :
- 2024
-
Abstract
- Objective: To study the value of three-dimensional CT (3D-CT) reconstruction by comparing the surgical effects of C-arm and 3D-CT in the treatment of trigeminal neuralgia (TN) by percutaneous balloon compression (PBC).<br />Methods: A total of 136 patients were included from May 2018 to February 2019. Among them, 65 patients underwent PBC treatment with 3D-CT and others with C-arm. During 3D-CT-guided operation, 3D-CT reconstruction software was used to analyze and measure the distances from the internal orifice of Foramen ovale (FO-I) and the external orifice of Foramen ovale (FO-E) to the top of the balloon (BT) and the petrous bone ridge (PR). The data, including the angle between the puncture needle direction and the zygomatic arch, petrous bone ridge, and slope, were used to assist the puncture and balloon plasty. Postoperative follow-up for more than five years was performed to evaluate the efficacy and pain recurrence.<br />Results: The distance from FO-E to PR was (2.10 ± 0.16)cm, the average distance from FO-I to BT was (2.39 ± 0.07)cm, and the average angles between the puncture needle and zygomatic arch, slope, and petrous bone ridge were (56.19 ± 5.59)°, (69.12 ± 6.92)°, and (104.49 ± 6.46)°, respectively. One (1.5 %) patient in the 3D-CT group and three (4.2 %) patients in the C-arm group failed to receive PBC treatment because of failure of FO puncture (P = 0.032).In terms of postoperative pain improvement, 3D-CT group achieved better results than the C-arm group (P = 0.043). There were no significant differences in the rates of major complications and short-term recurrence (P = 0.926) between the two groups after surgery, but the five-year recurrence rate in the 3D-CT group was lower than that in the C-arm group (P = 0.032).<br />Conclusion: By guiding the angle and depth of puncture, the intraoperative application of 3D-CT reconstruction technology can improve the accuracy of foramen ovale puncture and alleviate postoperative pain, and also maintain long-term postoperative pain relief, which can be used as a potentially better guidance method to improve the surgical efficacy of PBC.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024. Published by Elsevier Ltd.)
Details
- Language :
- English
- ISSN :
- 1532-2653
- Volume :
- 125
- Database :
- MEDLINE
- Journal :
- Journal of clinical neuroscience : official journal of the Neurosurgical Society of Australasia
- Publication Type :
- Academic Journal
- Accession number :
- 38772175
- Full Text :
- https://doi.org/10.1016/j.jocn.2024.05.012