Back to Search
Start Over
Comparative study of two laboratory techniques for the detection of HLA-B27 in patients with axial spondyloarthritis: a cross-sectional analysis.
- Source :
-
Advances in rheumatology (London, England) [Adv Rheumatol] 2024 May 23; Vol. 64 (1), pp. 42. Date of Electronic Publication: 2024 May 23. - Publication Year :
- 2024
-
Abstract
- Background: The diagnostic and prognostic relevance of Human Leukocyte Antigen B-27 (HLA-B27) in Axial Spondyloarthritis (AxSpA) is undeniable, with 70% of Ankylosing Spondylitis (AS) patients carrying the B27 gene, contrasted with a mere 4.35% in the general population. Flow cytometry (FC) and Polymerase Chain Reaction (PCR) have emerged as the predominant techniques for routine HLA-B27 typing. While various studies have compared these methods, none have catered to the unique characteristics of the Brazilian demographic. Therefore, this research aims to compare FC and PCR in a Brazilian cohort diagnosed with AxSpA.<br />Methods: An analytical cross-sectional study was undertaken involving 62 AxSpA outpatients from a Brazilian University Hospital. Both FC and PCR-SSP assays were utilized to ascertain HLA-B27 typing. The outcomes (either confirming or refuting the allele's presence) underwent rigorous scrutiny. Agreement between the methodologies was assessed using the kappa statistic. A p-value of < 0.05 was deemed statistically significant.<br />Results: Of the participants, 90.3% (n = 56) were HLA-B27 positive according to FC, while 79% (n = 49) were identified as positive using the PCR method. FC exhibited a sensitivity rate of 98% paired with a specificity of 38.5%. The Positive Predictive Value for FC stood at 85.7%, and the Negative Predictive Value was 83.5%. Consequently, the overall accuracy of the FC method was gauged at 85.5%. A kappa coefficient of κ = 0.454 was derived.<br />Conclusions: FC demonstrated noteworthy sensitivity and satisfactory accuracy in HLA-B27 detection, albeit with a reduced specificity when contrasted with PCR-SSP. Nevertheless, given its cost-effectiveness and streamlined operation relative to PCR, FC remains a pragmatic option for preliminary screening in clinical practice, especially in low-income regions. To optimize resource allocation, we advocate for a refined algorithm that initiates by assessing the relevance of HLA-B27 typing based on Choosing Wisely recommendations. It then leans on FC, and, if results are negative yet clinical suspicion persists, advances to PCR. This approach aims to balance diagnostic accuracy and financial prudence, particularly in regions contending with escalating medical costs.<br /> (© 2024. The Author(s).)
- Subjects :
- Humans
Cross-Sectional Studies
Male
Female
Adult
Axial Spondyloarthritis diagnosis
Brazil
Middle Aged
Sensitivity and Specificity
Spondylitis, Ankylosing diagnosis
Spondylitis, Ankylosing genetics
HLA-B27 Antigen genetics
HLA-B27 Antigen blood
HLA-B27 Antigen analysis
Polymerase Chain Reaction
Flow Cytometry
Subjects
Details
- Language :
- English
- ISSN :
- 2523-3106
- Volume :
- 64
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Advances in rheumatology (London, England)
- Publication Type :
- Academic Journal
- Accession number :
- 38783377
- Full Text :
- https://doi.org/10.1186/s42358-024-00383-x