Back to Search Start Over

Minimizing tearing during vaginal delivery with a perineal protection device: a randomized controlled trial.

Authors :
André K
Leijonhufvud Å
Ignell C
Källén K
Stuart A
Source :
American journal of obstetrics & gynecology MFM [Am J Obstet Gynecol MFM] 2024 Sep; Vol. 6 (9), pp. 101402. Date of Electronic Publication: 2024 Jun 15.
Publication Year :
2024

Abstract

Background: There is a growing body of evidence indicating that second-degree tears cause both short- and long-term consequences. Very few preventative measures have been found to reduce the incidence of these tears.<br />Objective: This study aimed to investigate whether the use of a perineal protection device during vaginal birth reduces severe perineal tearing (grade ≥2 tear) in primiparous women compared with routine manual perineal support.<br />Study Design: A single-center randomized controlled trial was conducted in Sweden from 2019 to 2021. Primiparous women at term were randomly allocated to the intervention group (n=43), where a perineal protection device was used, or to the routine care group (n=49). The primary outcome was grade of perineal tear. The secondary outcomes were vaginal and labial tearing. Continuous data were analyzed using the Student t test or Mann-Whitney U test. Dichotomous data were analyzed using the Pearson X <superscript>2</superscript> test, Fisher exact test, and ordinal logistic regression.<br />Results: Women in the intervention group had a significantly lower risk of sustaining more extensive perineal tearing than those in the control group. The use of the perineal protection device decreased the risk of grade ≥2 tears in relation to grade 0 to 1 tears (odds ratio, 0.40; 95% confidence interval, 0.17-0.94). Ordinal logistic regression analyses revealed an odds ratio of 0.36 (95% confidence interval, 0.16-0.81) per incremetn of grade injury using the perineal protection device vs routine care (P=.013). The number needed to treat using the perineal protection device was 4.3 to avoid 1 grade ≥2 tear. Women in the treatment group showed less labial tearing (P=.016). No adverse effect was detected.<br />Conclusion: The use of a perineal protection device reduced the risk of grade ≥2 perineal tearing by 60% and labial tearing. El resumen está disponible en Español al final del artículo.<br /> (Copyright © 2024 The Author(s). Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
2589-9333
Volume :
6
Issue :
9
Database :
MEDLINE
Journal :
American journal of obstetrics & gynecology MFM
Publication Type :
Academic Journal
Accession number :
38880240
Full Text :
https://doi.org/10.1016/j.ajogmf.2024.101402