Back to Search
Start Over
Transition from WATCHMAN generation-2.5 device to WATCHMAN FLX device for percutaneous left atrial appendage closure: Incidence and predictors of device-related thrombosis and short- to mid-term outcomes.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2024 Aug; Vol. 104 (2), pp. 318-329. Date of Electronic Publication: 2024 Jun 19. - Publication Year :
- 2024
-
Abstract
- Background: Patients with nonvalvular atrial fibrillation (AF) not suitable for long-term anticoagulant therapy undergo percutaneous left atrial appendage closure (LAAC) using the WATCHMAN device. The safety and efficacy of WATCHMAN-FLX (WM-FLX) compared with WATCHMAN-2.5 (WM-2.5), particularly in Asian populations, is unknown.<br />Methods: We evaluated the background, procedure, and clinical outcomes of 199 patients who underwent LAAC between September 2019 and December 2022 and compared WM-2.5 (72 patients) with WM-FLX (127 patients).<br />Results: The mean age was 76 years, with 128 men, and 100 had nonparoxysmal AF (non-PAF). The mean CHA <subscript>2</subscript> DS <subscript>2</subscript> -VASc, and HAS-BLED were 5.1, and 3.2 points, respectively. WM-FLX group demonstrated a shorter procedure time than WM-2.5 group (50 vs. 42 min, p = 0.001). The WM-FLX group demonstrated no procedural-related acute cardiac tamponade, which was significantly low (5.6% vs. 0%, p = 0.02), and a significantly higher rate of complete seal at 45-day (63% vs. 80%, p = 0.04). WM-FLX group had a significantly higher cumulative 1-year incidence of device-related thrombosis (DRT) than WM-2.5 group (3.4% vs. 7.0%, Log-rank p = 0.01). Univariate analysis identified two DRT risk factors in the WM-FLX group: non-PAF (odds ratio [OR] 7.72; 95% confidence interval [CI] 1.20-48.7; p = 0.04), and 35-mm device (OR 5.13; 95% CI 1.31-19.8; p = 0.02).<br />Conclusions: WM-FLX significantly improved the procedural quality and safety of LAAC. However, DRT remains an important issue even in the novel LAAC device, being a hazard for patients with high DRT risk, such as having non-PAF and using 35-mm devices.<br /> (© 2024 Wiley Periodicals LLC.)
- Subjects :
- Aged
Female
Humans
Male
Atrial Appendage physiopathology
Atrial Appendage diagnostic imaging
Incidence
Prosthesis Design
Retrospective Studies
Risk Assessment
Risk Factors
Stroke etiology
Stroke prevention & control
Time Factors
Treatment Outcome
Atrial Fibrillation physiopathology
Atrial Fibrillation diagnosis
Atrial Fibrillation therapy
Left Atrial Appendage Closure adverse effects
Left Atrial Appendage Closure instrumentation
Thrombosis etiology
Thrombosis prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 104
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 38895767
- Full Text :
- https://doi.org/10.1002/ccd.31111