A surgical instrument motion measurement system for skill evaluation in practical laparoscopic surgery training.

Authors :
Ebina K
Abe T
Yan L
Hotta K
Shichinohe T
Higuchi M
Iwahara N
Hosaka Y
Harada S
Kikuchi H
Miyata H
Matsumoto R
Osawa T
Kurashima Y
Watanabe M
Kon M
Murai S
Komizunai S
Tsujita T
Sase K
Chen X
Senoo T
Shinohara N
Konno A
Source :
PloS one [PLoS One] 2024 Jun 25; Vol. 19 (6), pp. e0305693. Date of Electronic Publication: 2024 Jun 25 (Print Publication: 2024).
Publication Year :
2024

Abstract

This study developed and validated a surgical instrument motion measurement system for skill evaluation during practical laparoscopic surgery training. Owing to the various advantages of laparoscopic surgery including minimal invasiveness, this technique has been widely used. However, expert surgeons have insufficient time for providing training to beginners due to the shortage of surgeons and limited working hours. Skill transfer efficiency has to be improved for which there is an urgent need to develop objective surgical skill evaluation methods. Therefore, a simple motion capture-based surgical instrument motion measurement system that could be easily installed in an operating room for skill assessment during practical surgical training was developed. The tip positions and orientations of the instruments were calculated based on the marker positions attached to the root of the instrument. Because the patterns of these markers are individual, this system can track multiple instruments simultaneously and detect exchanges. However due to the many obstacles in the operating room, the measurement data included noise and outliers. In this study, the effect of this decrease in measurement accuracy on feature calculation was determined. Accuracy verification experiments were conducted during wet-lab training to demonstrate the capability of this system to measure the motion of surgical instruments with practical accuracy. A surgical training experiment on a cadaver was conducted, and the motions of six surgical instruments were measured in 36 cases of laparoscopic radical nephrectomy. Outlier removal and smoothing methods were also developed and applied to remove the noise and outliers in the obtained data. The questionnaire survey conducted during the experiment confirmed that the measurement system did not interfere with the surgical operation. Thus, the proposed system was capable of making reliable measurements with minimal impact on surgery. The system will facilitate surgical education by enabling the evaluation of skill transfer of surgical skills.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2024 Ebina et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
19
Issue :
6
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
38917181
Full Text :
https://doi.org/10.1371/journal.pone.0305693