Back to Search
Start Over
Clinical Applications for Spread of Excitation Functions Obtained Via Electrically Evoked Compound Action Potentials (eCAP).
- Source :
-
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology [Otol Neurotol] 2024 Aug 01; Vol. 45 (7), pp. 790-797. Date of Electronic Publication: 2024 Jun 26. - Publication Year :
- 2024
-
Abstract
- Objectives: To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample.<br />Study Design: Retrospective case review.<br />Setting: Cochlear implant (CI) program at a tertiary medical center.<br />Patients: Two hundred seventy-two ears (238 patients) with Cochlear Ltd. CIs (mean age = 46 yr, range = 9 mo-93 yr, 50% female) implanted between August 2014 and December 2022 were included.<br />Main Outcome Measures: eCAP SOE widths (mm) (probe electrodes 5, 11, and 17), incidence of electrode tip fold-over, CT imaging data (electrode-to-modiolus distance, angular insertion depth, scalar location), and speech recognition outcomes (consonant-nucleus-consonant [CNC], AzBio quiet, and +5 dB SNR) through the first year after CI activation.<br />Results: 1) eCAP SOE demonstrated a sensitivity of 85.7% for identifying tip fold-over instances that were confirmed by CT imaging. In the current dataset, the tip fold-over incidence rate was 3.1% (7 patients), with all instances involving a precurved electrode array. 2) There was a significant positive relationship between eCAP SOE and mean electrode-to-modiolus distance for precurved arrays, and a significant positive relationship between eCAP SOE and angular insertion depth for straight arrays. No relationships between eCAP SOE and scalar location or cochlea diameter were found in this sample. 3) There were no significant relationships between eCAP SOE and speech recognition outcomes for any measure or time point, except for a weak negative correlation between average eCAP SOE widths and CNC word scores at 6 months post-activation for precurved arrays.<br />Conclusions: In the absence of intraoperative CT or fluoroscopic imaging, eCAP SOE is a reasonable alternative method for identifying electrode array tip fold-over and should be routinely measured intraoperatively, especially for precurved electrode arrays with a sheath.<br />Competing Interests: Sources of support and disclosure of funding: Dr. Gifford is on the audiology advisory boards for Advanced Bionics and Cochlear Americas and is a consultant for Skylark Bio. The remaining authors disclose no conflicts of interest.<br /> (Copyright © 2024, Otology & Neurotology, Inc.)
- Subjects :
- Humans
Female
Male
Middle Aged
Aged
Adult
Retrospective Studies
Aged, 80 and over
Child, Preschool
Young Adult
Adolescent
Child
Infant
Evoked Potentials, Auditory physiology
Tomography, X-Ray Computed
Cochlear Implantation methods
Cochlear Implants
Speech Perception physiology
Action Potentials physiology
Subjects
Details
- Language :
- English
- ISSN :
- 1537-4505
- Volume :
- 45
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
- Publication Type :
- Academic Journal
- Accession number :
- 38923968
- Full Text :
- https://doi.org/10.1097/MAO.0000000000004242