Back to Search Start Over

A phosphorylated guanidine chitosan and UiO-66-NH 2 modified magnetic nanoparticle platform for enrichment and detection of multiple bacteria.

Authors :
Xu K
Zhu J
Zhang T
Sui G
Source :
Talanta [Talanta] 2024 Oct 01; Vol. 278, pp. 126435. Date of Electronic Publication: 2024 Jun 19.
Publication Year :
2024

Abstract

Wastewater-based epidemiology (WBE) is a powerful tool for early warning of infectious disease outbreaks. Hence, a rapid and portable pathogen monitoring system is urgent needed for on-site detection. In this work, we first reported synthesis of an artificial modulated wide-spectrum bacteria capture nanoparticle (Arg-CSP@UiO@Fe <subscript>3</subscript> O <subscript>4</subscript> ). Arginine-modified phosphorylated chitosan (Arg-CSP) coating could provide strongly positive charged guanidinium group for pathogen interaction by electrostatic attraction, and UiO-66-NH <subscript>2</subscript> layer could help Arg-CSP graft onto Fe <subscript>3</subscript> O <subscript>4</subscript> magnetic particles. The capture efficiency of Arg-CSP@UiO@Fe <subscript>3</subscript> O <subscript>4</subscript> reached 92.2 % and 97.3 % for Escherichia coli (E.coli) and Staphylococcus epidermidis (S.epidermidis)within 40 min, in 10 mL sample. To prevent pathogen degradation in sewage, a portable nucleic acid extraction-free method was also developed. UiO-66-NH <subscript>2</subscript> could disintegrate in buffer with high concentration of PO <subscript>4</subscript> <superscript>3-</superscript> for bacterium desorption, and then nucleic acid of the bacteria was released by heating. The DNA template concentration obtained by this method was 779.28 times higher than that of the direct thermal lysis product and 8.63 times higher than that of the commercial kit. Afterwards, multiple detection of bacteria was realized by loop-mediated isothermal amplification (LAMP). Artificial regulated pathogen desorption could prevent non-specific adsorption of nucleic acid by nanoparticles. The detection limit of Arg-CSP@UiO@Fe <subscript>3</subscript> O <subscript>4</subscript> -LAMP method was 80 cfu/mL for E.coli and 300 cfu/mL for S.epidermidis. The accuracy and reliability of the method was validated by spiked sewage samples. In conclusion, this bio-monitoring system was able to detect multiple bacteria in environment conveniently and have good potential to become an alternative solution for rapid on-site pathogen detection.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024. Published by Elsevier B.V.)

Details

Language :
English
ISSN :
1873-3573
Volume :
278
Database :
MEDLINE
Journal :
Talanta
Publication Type :
Academic Journal
Accession number :
38924986
Full Text :
https://doi.org/10.1016/j.talanta.2024.126435