Back to Search
Start Over
Simplified liver imaging reporting and data system for the diagnosis of hepatocellular carcinoma on gadoxetic acid-enhanced magnetic resonance imaging.
- Source :
-
World journal of gastrointestinal oncology [World J Gastrointest Oncol] 2024 Jun 15; Vol. 16 (6), pp. 2439-2448. - Publication Year :
- 2024
-
Abstract
- Background: The liver imaging reporting and data system (LI-RADS) diagnostic table has 15 cells and is too complex. The diagnostic performance of LI-RADS for hepatocellular carcinoma (HCC) is not satisfactory on gadoxetic acid-enhanced magnetic resonance imaging (EOB-MRI).<br />Aim: To evaluate the ability of the simplified LI-RADS (sLI-RADS) to diagnose HCC on EOB-MRI.<br />Methods: A total of 331 patients with 356 hepatic observations were retrospectively analysed. The diagnostic performance of sLI-RADS A-D using a single threshold was evaluated and compared with LI-RADS v2018 to determine the optimal sLI-RADS. The algorithms of sLI-RADS A-D are as follows: The single threshold for sLI-RADS A and B was 10 mm, that is, classified observations ≥ 10mm using an algorithm of 10-19 mm observations (sLI-RADS A) and ≥ 20 mm observations (sLI-RADS B) in the diagnosis table of LI-RADS v2018, respectively, while the classification algorithm remained unchanged for observations < 10 mm; the single threshold for sLI-RADS C and D was 20 mm, that is, for < 20 mm observations, the algorithms for < 10 mm observations (sLI-RADS C)and 10-19 mm observations (sLI-RADS D) were used, respectively, while the algorithm remained unchanged for observations ≥ 20 mm. With hepatobiliary phase (HBP) hypointensity as a major feature (MF), the final sLI-RADS (F-sLI-RADS) was formed according to the optimal sLI-RADS, and its diagnostic performance was evaluated. The times needed to classify the observations according to F-sLI-RADS and LI-RADS v2018 were compared.<br />Results: The optimal sLI-RADS was sLI-RADS D (with a single threshold of 20 mm), because its sensitivity was greater than that of LI-RADS v2018 (89.8% vs 87.0%, P = 0.031), and its specificity was not lower (89.4% vs 90.1%, P > 0.999). With HBP hypointensity as an MF, the sensitivity of F-sLI-RADS was greater than that of LI-RADS v2018 (93.0% vs 87.0%, P < 0.001) and sLI-RADS D (93.0% vs 89.8%, P = 0.016), without a lower specificity (86.5% vs 90.1%, P = 0.062; 86.5% vs 89.4%, P = 0.125). Compared with that of LI-RADS v2018, the time to classify lesions according to F-sLI-RADS was shorter (51 ± 21 s vs 73 ± 24 s, P < 0.001).<br />Conclusion: The use of sLI-RADS with HBP hypointensity as an MF may improve the sensitivity of HCC diagnosis and reduce lesion classification time.<br />Competing Interests: Conflict-of-interest statement: The authors of this manuscript have no conflicts of interest to disclose.<br /> (©The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1948-5204
- Volume :
- 16
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- World journal of gastrointestinal oncology
- Publication Type :
- Academic Journal
- Accession number :
- 38994131
- Full Text :
- https://doi.org/10.4251/wjgo.v16.i6.2439