Back to Search
Start Over
A dried sweat spot paper (DSSP) method based on novel mass spectrometry probe labeling for detection and resolution of DL-lactate enantiomers as potential biomarkers for diabetes mellitus.
- Source :
-
Analytica chimica acta [Anal Chim Acta] 2024 Aug 15; Vol. 1317, pp. 342914. Date of Electronic Publication: 2024 Jun 26. - Publication Year :
- 2024
-
Abstract
- Background: Human sweat can be collected non-invasively with low infectivity; however, its application as a determination method has been challenged due to the presence of trace amounts of chiral metabolites. Moreover, its application as a biological fluid for disease diagnosis has not been previously reported. In this study, the human dried sweat spot paper (DSSP) method was proposed for the derivatization of a novel mass spectrometric chiral probe, N-[1-Oxo-5-(triphenylphosphonium) pentyl]-(S)-3-aminopyrrolidine (OTPA), determination and resolution of DL-lactic acid (DL-LA) enantiomers in human elbow sweat.<br />Results: The methodological validation revealed the resolution (Rs) as 1.78, the limit of detection (S/N = 3) as 20.83 fmol, good linearity (R <superscript>2</superscript>  ≥ 0.9996), and the intra-day and intra-day stability with RSD ranging from 0.53 to 10.85 %, while the average recovery rate of D-LA and L-LA were 104.00 % ± 4.68 % and 107.41 % ± 8.34 %, respectively, with high accuracy. In addition, the method was applied for the determination of DL-LA in the sweat on elbow of 10 healthy volunteers and 30 diabetic patients. The results demonstrated that the D/L ratio and L/D ratio were significantly different (p < 0.0001). In addition, a moderate positive linear correlation between the D/L-LA ratio in human sweat and fasting blood glucose level (r = 0.7744, p < 0.0001) was observed, thereby suggesting that the D/L ratio of lactate in human sweat correlate the glucose level in human fasting blood.<br />Significance and Novelty: The D/L lactate ratio in human sweat could be used as a potential biomarker for diabetes screening. The method can be used to screen for diabetes by providing a dry sweat paper to test equipment and has the potential to be a non-invasive early-warning diagnostic tool for diabetes.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1873-4324
- Volume :
- 1317
- Database :
- MEDLINE
- Journal :
- Analytica chimica acta
- Publication Type :
- Academic Journal
- Accession number :
- 39030012
- Full Text :
- https://doi.org/10.1016/j.aca.2024.342914