Back to Search Start Over

Numerical computation of heat transfer, moisture transport and thermal comfort through walls of buildings made of concrete material in the city of Douala, Cameroon: An ab initio investigation.

Authors :
Moyou AY
Njifenjou A
Tiam Kapen P
Fokwa D
Source :
Heliyon [Heliyon] 2024 Jul 03; Vol. 10 (13), pp. e34058. Date of Electronic Publication: 2024 Jul 03 (Print Publication: 2024).
Publication Year :
2024

Abstract

The buildings of the city of Douala in Cameroon have been experiencing degradation for several decades due to the climate characterized by high humidity and oppressive heat. As a result, large grayish or black stains can be observed on these buildings. We sometimes witness the subsidence of the slab of the balconies, the cracking of the walls and the collapse of the buildings worn by the humidity. These damages are generally caused by infiltration and capillary rise. In addition, it has been demonstrated that people living in damp buildings are at risk of illnesses such as asthma and lung infections. Therefore, the novelty of this work is threefold: (i) it proposes for the very first time a numerical study of the transport of humidity and heat through the porous walls of buildings constructed with concrete material, the main construction material in the city of Douala; (ii) It was determined what level of indoor thermal comfort was appropriate for sleeping inside a real three-dimensional G+1 complex residential building constructed with concrete blocks; and (iii) Using the geographical coordinates, and time data, the sun radiation's direction of incidence was assessed throughout the simulation. The computation was performed using Comsol Multiphysics 6.0 software. The distributions of temperature, relative humidity as well as moisture level were presented at various periods. It appears from the results that face to this high humidity, the concrete material retains a large quantity of water for a considerable periods of time, which weakens the steel reinforcement of concrete which is corroded by rust. The computation of thermal comfort in the 3D building showed that the various rooms of the building were not comfortable during the night since temperature inside the building increased progressively due to diffusion of heat. In addition, the numerical solutions indicated that the energy stored within the walls diffused from the external walls to the internal walls during the night. It was also demonstrated that the walls of the building were warmer than the windows, doors and the roof at the computational times, which simply revealed a greater storage capacity of heat in the concrete blocks material. The findings highlighted that the temperature decreased rapidly in a thickness of 0.06 m of the concrete block during the nine days and this decrease was attenuated in the second part of the thickness of the concrete block (0.14 m).<br />Competing Interests: The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (© 2024 The Author(s).)

Details

Language :
English
ISSN :
2405-8440
Volume :
10
Issue :
13
Database :
MEDLINE
Journal :
Heliyon
Publication Type :
Academic Journal
Accession number :
39055847
Full Text :
https://doi.org/10.1016/j.heliyon.2024.e34058