Back to Search
Start Over
Feasibility of intentional bioprosthetic valve fracture in the tricuspid position.
- Source :
-
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions [Catheter Cardiovasc Interv] 2024 Sep; Vol. 104 (3), pp. 523-530. Date of Electronic Publication: 2024 Aug 01. - Publication Year :
- 2024
-
Abstract
- Background: Transcatheter tricuspid valve-in-valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.<br />Aims: Evaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.<br />Methods: An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow-up data were collected. Comparison was made to the pre- and post-ViV replacement with fracture of the tricuspid valve frame conditions.<br />Results: Ten patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3-5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.<br />Conclusion: Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.<br /> (© 2024 The Author(s). Catheterization and Cardiovascular Interventions published by Wiley Periodicals LLC.)
- Subjects :
- Humans
Female
Male
Treatment Outcome
Adult
Time Factors
Hemodynamics
Young Adult
Retrospective Studies
Recovery of Function
United States
Adolescent
Middle Aged
Heart Valve Prosthesis
Feasibility Studies
Heart Valve Prosthesis Implantation instrumentation
Heart Valve Prosthesis Implantation adverse effects
Bioprosthesis
Prosthesis Design
Registries
Tricuspid Valve diagnostic imaging
Tricuspid Valve surgery
Tricuspid Valve physiopathology
Prosthesis Failure
Cardiac Catheterization instrumentation
Cardiac Catheterization adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1522-726X
- Volume :
- 104
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
- Publication Type :
- Academic Journal
- Accession number :
- 39087728
- Full Text :
- https://doi.org/10.1002/ccd.31168