Back to Search Start Over

Diagnostic performance of ultrasound reporting systems in evaluation of adnexal masses: A prospective observational study.

Authors :
Kapoor S
Singhal S
Dhamija E
Manchanda S
Malhotra N
Bhatla N
Source :
European journal of obstetrics, gynecology, and reproductive biology [Eur J Obstet Gynecol Reprod Biol] 2024 Oct; Vol. 301, pp. 186-193. Date of Electronic Publication: 2024 Aug 13.
Publication Year :
2024

Abstract

Objective(s): To evaluate and compare diagnostic performance of ultrasound-based reporting systems IOTA SR, ADNEX, GIRADS, ORADS for discrimination between benign and malignant adnexal masses.<br />Study Design: A prospective observational study in a tertiary care hospital's Obstetrics and Gynaecology department evaluated pre-operative ultrasound imaging for adnexal masses in 80 cases, comparing various reporting systems' sensitivity and specificity against histopathology as gold standard using STATA version 17.0 for data analysis.<br />Results: Among the 80 masses, 55 % (44/80) were confirmed as benign on histopathology, while 45 % were identified as malignant. The sensitivity and specificity of SR was 100 % (95 %CI: 90.0-100) and 97.1 % (95 %CI: 84.7-99.9) respectively. Eleven masses (13.8 %) were inconclusive, reducing specificity to 75 % (95 %CI:59.7-86.8).In ADNEX optimal cut-off for risk of malignancy was 34.1 % with sensitivity of 86.1 % (95 % CI: 70.5-95.3) and specificity of 90.9 % (95 % CI: 78.3-97.5). Considering GIRADS 4-5 and risk threshold of ≥10 % (ORADS 4-5) as predictors of malignancy sensitivity was 100 % (95 %CI: 90.3-100) and specificity was 70.5 % (95 %CI: 54.8-83.2) for GIRADS and ORADS. All reporting systems were comparable (p = 0.7). ADNEX identified 72.7 % (8/11) of inconclusive cases, outperforming GIRADS/ORADS which correctly classified 27.2 % (3/11) cases. When applied to misclassified GIRADS/ORADS 4-5 category, ADNEX demonstrated superior performance by correctly classifying 76.9 % (10/13) masses, while SR achieved correct classification in only 38.5 % (5/13) masses.<br />Conclusion(s): All classification systems showed comparable accuracy in malignancy risk identification on imaging. GIRADS/ORADS tended to overestimate malignancy risk. The present study recommends a two-step strategy, leveraging higher specificity of ADNEX model for improved stratification of adnexal masses.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1872-7654
Volume :
301
Database :
MEDLINE
Journal :
European journal of obstetrics, gynecology, and reproductive biology
Publication Type :
Academic Journal
Accession number :
39153388
Full Text :
https://doi.org/10.1016/j.ejogrb.2024.08.023