Back to Search Start Over

The diagnostic value and validation of IL-22 combimed with sCD40L in tuberculosis pleural effusion.

Authors :
Xu Y
Wu J
Yao Q
Liu Q
Chen H
Zhang B
Liu Y
Wang S
Shao L
Zhang W
Ou Q
Gao Y
Source :
BMC immunology [BMC Immunol] 2024 Oct 09; Vol. 25 (1), pp. 66. Date of Electronic Publication: 2024 Oct 09.
Publication Year :
2024

Abstract

Background: There is substantial evidence indicating that cytokines play a role in the immune defense against tuberculosis. This study aims to evaluate the levels of various cytokines in pleural effusion to ditinguish between tuberculosis pleurisy and malignant pleurisy.<br />Methods: A total of 82 participants with pleural effusion were included in the training cohort, and 76 participants were included in the validation cohort. The individuals were divided into tuberculosis and malignant pleurisy groups. The concentrations of interleukin-1β (IL-1β), IL-4, IL-6, IL-10, IL-17 A, IL-17 F, IL-21, IL-22, IL-25, IL-31, IL-33, interferon-γ (IFN-γ), soluble CD40 ligand (sCD40L) and tumor necrosis factor-α (TNF-α) in pleural effusion were measured using a multiplex cytokine assay. The threshold values were calculated according to the receiver operating characteristic (ROC) curve analysis to aid in diagnosing tuberculosis pleurisy. Furthermore, the combined measure was validated in the validation cohort.<br />Results: The levels of all 14 cytokines in pleural effusion were significantly higher in participants with tuberculosis compared to those with malignant pleurisy (all P < 0.05). The area under the curve (AUC) was ≥ 0.920 for the IL-22, sCD40L, IFN-γ, TNF-α and IL-31, which were significantly increased in tuberculous pleural effusion (TPE) compared to MPE in the training cohort. Threshold values of 95.80 pg/mL for IFN-γ, 41.80 pg/mL for IL-31, and 18.87 pg/mL for IL-22 provided ≥ 90% sensitivity and specificity in distinguishing between tuberculosis pleurisy and malignant pleurisy in the training cohort. Among these, IL-22 combined with sCD40L showed the best sensitivity and specificity (94.0% and 96.9%) for diagnosing tuberculosis pleurisy, and this finding was validated in the validation cohort.<br />Conclusion: We demonstrated that the levels of IL-1β, IL-4, IL-6, IL-10, IL-17 A, IL-17 F, IL-21, IL-22, IL-25, IL-31, IL-33, IFN-γ, sCD40L and TNF-α in pleural effusion had significant difference between tuberculosis pleurisy and malignant pleurisy. Specifically, IL-22 ≥ 18.87 pg/mL and sCD40L ≥ 53.08 pg/mL can be clinically utilized as an efficient diagnostic strategy for distinguishing tuberculosis pleurisy from malignant pleurisy.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
1471-2172
Volume :
25
Issue :
1
Database :
MEDLINE
Journal :
BMC immunology
Publication Type :
Academic Journal
Accession number :
39385103
Full Text :
https://doi.org/10.1186/s12865-024-00652-w