Back to Search Start Over

Efficacy and safety of videolaryngoscopes for transesophageal echocardiography probe insertion: A trial sequential meta-analysis.

Authors :
Hung KC
Wang WT
Yu CH
Wu JY
Lin CM
Liu WC
Lin TC
Chen IW
Source :
PloS one [PLoS One] 2024 Oct 10; Vol. 19 (10), pp. e0311234. Date of Electronic Publication: 2024 Oct 10 (Print Publication: 2024).
Publication Year :
2024

Abstract

Objective: This meta-analysis aimed to compare videolaryngoscope (VL)-assisted transesophageal echocardiography (TEE) probe insertion with conventional methods in terms of efficacy and safety.<br />Methods: Several major databases such as Medline and Embase were systematically searched to identified relevant studies from inception to June 2024. The primary outcome was complication rate, defined as the proportion of patients experiencing complications related to TEE probe insertion. Injuries at specific sites (e.g., posterior hypopharyngeal wall) from both groups were also analyzed. The secondary outcomes included the first-attempt success rate and total insertion time of VL and conventional methods.<br />Results: Seven trials involving 716 participants were identified. The use of VL was found to significantly reduce the complication rate (risk ratio[RR]:0.28, 95% confidence interval[CI]:0.17-0.46, P < 0.00001) and increased the first-attempt success rate [FASR] (RR:1.33, 95%CI: 1.10-1.60, P = 0.003) compared with conventional methods. These findings were confirmed by trial sequential analysis. No significant difference was found in the TEE insertion time among the two techniques (mean difference: -2.94s, 95%CI: -10.28-4.4, P = 0.43). VL significantly reduced the risk of trauma to the hypopharyngeal wall but showed no significant benefits in other areas (e.g., pyriform sinus). The certainty of evidence was moderate for the complication rate, very low for the FAS rate, and low for the TEE insertion time.<br />Conclusion: The use of VL for TEE probe insertion is associated with a significantly lower complication rate and higher FAS rate than conventional methods. These findings suggest that VL enhances patient safety and improves the efficiency of TEE probe insertion.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2024 Hung et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1932-6203
Volume :
19
Issue :
10
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
39388404
Full Text :
https://doi.org/10.1371/journal.pone.0311234