Back to Search
Start Over
Continuous glucose monitoring (Dexcom g6) in people with diabetes after kidney transplantation.
- Source :
-
Renal failure [Ren Fail] 2024 Dec; Vol. 46 (2), pp. 2413007. Date of Electronic Publication: 2024 Oct 11. - Publication Year :
- 2024
-
Abstract
- Objectives: Use of continuous glucose monitoring-CGM in patients on kidney replacement therapy including kidney transplant recipients, may improve glycemic control and detection of hypoglycemia. However, studies in this population in particular in kidney transplant recipients are very limited.<br />Methods: The study aimed to evaluate glycemic profiles using the Dexcom G6 CGM system for 30 d a personal smartphone in people with diabetes after kidney transplantation and to assess the impact of monthly use of the CGM system on glycemic control and quality of life in this group.<br />Results: Over 8 months, 9 people after kidney transplantation were included in the study (7 women, median age 57 years), 8 people with new-onset diabetes after transplantation (NODAT), and 1 person with diabetes mellitus type 1. The time since kidney transplantation in each of the study participants was less than 2 years. In 7 people with NODAT, the time in range was above 70%. In all study participants, hyperglycemia was observed mainly in the afternoon (2-6 pm). In some patients, pressure-induced sensor attenuations (PISAs) were noted. There was no effect of the use of Dexcom G6 on the HbA1c value. There was no impact of the use of the Dexcom G6 system on the perception of overall quality of life, but monthly use had a positive impact on the perception of the quality of health.<br />Conclusions: CGM systems seem to be a promising method for assessing glycemic control in people with diabetes after kidney transplantation. More extensive research is needed to assess safety and usefulness in everyday practice.
- Subjects :
- Humans
Female
Middle Aged
Male
Aged
Adult
Diabetes Mellitus, Type 1 blood
Diabetes Mellitus, Type 1 complications
Glycated Hemoglobin analysis
Hypoglycemia etiology
Hypoglycemia diagnosis
Hypoglycemia blood
Smartphone
Hyperglycemia etiology
Hyperglycemia diagnosis
Hyperglycemia blood
Continuous Glucose Monitoring
Kidney Transplantation adverse effects
Quality of Life
Blood Glucose Self-Monitoring
Blood Glucose analysis
Subjects
Details
- Language :
- English
- ISSN :
- 1525-6049
- Volume :
- 46
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Renal failure
- Publication Type :
- Academic Journal
- Accession number :
- 39392129
- Full Text :
- https://doi.org/10.1080/0886022X.2024.2413007