Back to Search
Start Over
Comparative clinical efficacy of "Figure-8" Banding and double-row anchor suture-bridge fixation in arthroscopic management of tibial intercondylar eminence avulsion fractures.
- Source :
-
Journal of orthopaedic surgery and research [J Orthop Surg Res] 2024 Oct 16; Vol. 19 (1), pp. 663. Date of Electronic Publication: 2024 Oct 16. - Publication Year :
- 2024
-
Abstract
- Objective: The objective of this study is to assess and compare the clinical efficacy of "Figure-8" banding and double-row anchor suture-bridge fixation techniques in the arthroscopic management of tibial intercondylar eminence avulsion fractures.<br />Method: A retrospective analysis was conducted on the medical records of 42 patients who underwent arthroscopic surgery for tibial intercondylar eminence fractures at our institution from June 2017 to June 2022. This cohort included 20 cases treated with "Figure-8" banding and 22 cases managed using double-row anchor suture-bridge fixation. Comparative assessments were made regarding operative duration, duration of fracture consolidation, postoperative knee joint range of motion, joint stability as assessed by the Lachman test, Lysholm score, and International Knee Documentation Committee (IKDC) functional score for both treatment groups.<br />Results: The mean follow-up duration was 13.8 months. The analysis indicated that the double-row anchor suture-bridge group had a significantly longer operative duration compared to the "Figure-8" banding group (p < 0.05). Postoperative computed tomography (CT) scans confirmed successful reduction in both groups, with fracture consolidation achieved within an average of three months. Both groups showed significant improvements in postoperative knee range of motion, joint stability, and functional scores compared to preoperative measurements (p < 0.05). During the initial two-month post-surgery, the double-row anchor suture-bridge group demonstrated superior knee joint range of motion and functional scores compared to the "Figure-8" banding group (p < 0.05); however, these differences were not statistically significant beyond three months post-surgery (p > 0.05). By the one-year postoperative mark, joint stability outcomes were comparable between the two treatment groups (p > 0.05).<br />Conclusion: Both "Figure-8" banding and double-row anchor suture-bridge fixation techniques in the arthroscopic management of tibial intercondylar eminence avulsion fractures can achieve precise reduction and stable fixation. In addition, the figure-8 suture group has the characteristics of shorter surgery time and less cost. Notably, early postoperative knee function appears to be superior with double-row anchor suture-bridge fixation compared to "Figure-8" banding.<br /> (© 2024. The Author(s).)
- Subjects :
- Humans
Male
Retrospective Studies
Female
Adult
Middle Aged
Treatment Outcome
Fractures, Avulsion surgery
Fractures, Avulsion diagnostic imaging
Suture Anchors
Fracture Fixation, Internal methods
Range of Motion, Articular
Follow-Up Studies
Young Adult
Operative Time
Tibial Fractures surgery
Tibial Fractures diagnostic imaging
Arthroscopy methods
Suture Techniques
Subjects
Details
- Language :
- English
- ISSN :
- 1749-799X
- Volume :
- 19
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of orthopaedic surgery and research
- Publication Type :
- Academic Journal
- Accession number :
- 39407246
- Full Text :
- https://doi.org/10.1186/s13018-024-05111-1