Back to Search
Start Over
Feasibility of IAPWG protocol in performing high-definition three-dimensional anorectal manometry: A prospective, multicentric italian study.
- Source :
-
Techniques in coloproctology [Tech Coloproctol] 2024 Oct 31; Vol. 28 (1), pp. 145. Date of Electronic Publication: 2024 Oct 31. - Publication Year :
- 2024
-
Abstract
- Background: The International Anorectal Physiology Working Group (IAPWG) suggests a standardized protocol to perform high-resolution anorectal manometry. The applicability and possible limitations of the IAPWG protocol in performing three-dimensional high-definition anorectal manometry (3D-ARM) have still to be extensively evaluated.<br />Methods: The IAPWG protocol was applied in performing 3D-ARM. Anorectal manometry (ARM) and a balloon expulsion test (BET) were performed according to IAPGW protocol in 290 patients.<br />Key Results: A total of 84 males and 206 females (mean age 57.1 ± 15.7 years) were enrolled in six Italian centers. The reasons for which the patients were sent to perform 3D-ARM were: constipation (53.1%), fecal incontinence (26.9%), anal pain (3.1%), postsurgical (3.8%) and presurgical evaluation (4.8%), prolapse (3.4%), anal fissure (2.8%), and other (2.1%). Due to organic and functional conditions (low rectal anterior resections, rectal prolapses, and J-pouch after colectomy), we were unable to perform a complete 3D-ARM on six patients. Overall, a complete 3D-ARM and BET following IAPWG protocol was carried out in 284 patients (97.9%). The following were recorded: rest pressure (81.9 ± 32.0 mmHg) and length of the anal sphincter (37.0 ± 6.2 cm), maximum anal squeeze pressure (201.6 ± 81.3 mmHg), squeeze duration (22.0 ± 8.8 s), maximum rectal (48.7 ± 41.0 mmHg) and minimum anal pressure (73.3 ± 36.5 mmHg) during push, presence/absence of a dyssynergic pattern, cough reflex and rectal sensations (first constant sensation 48.4 ± 29.5 mL, desire to defecate 83.7 ± 52.1 mL, and maximum tolerated volume 149.5 ± 72.6 mL), and presence/absence of rectoanal inhibitory reflex. Mean 3D-ARM registration time was 14 min 7 s ± 3 min 12 s.<br />Conclusions: This is the first multicentric study that evaluates the applicability of the IAPWG protocol in 3D-ARM performed in different manometric laboratories (both gastroenterological and surgical). The IAPWG protocol was easy to perform and was not time consuming. A diagnosis according to the London Classification was easily obtained in most patients in which 3D-ARM was carried out. No clear limitations to the applicability of the IAPWG protocol were detected.<br /> (© 2024. Springer Nature Switzerland AG.)
Details
- Language :
- English
- ISSN :
- 1128-045X
- Volume :
- 28
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Techniques in coloproctology
- Publication Type :
- Academic Journal
- Accession number :
- 39480607
- Full Text :
- https://doi.org/10.1007/s10151-024-03028-9