Back to Search
Start Over
129 Xe Image Processing Pipeline: An open-source, graphical user interface application for the analysis of hyperpolarized 129 Xe MRI.
- Source :
-
Magnetic resonance in medicine [Magn Reson Med] 2025 Mar; Vol. 93 (3), pp. 1220-1237. Date of Electronic Publication: 2024 Oct 31. - Publication Year :
- 2025
-
Abstract
- Purpose: Hyperpolarized <superscript>129</superscript> Xe MRI presents opportunities to assess regional pulmonary microstructure and function. Ongoing advancements in hardware, sequences, and image processing have helped it become increasingly adopted for both research and clinical use. As the number of applications and users increase, standardization becomes crucial. To that end, this study developed an executable, open-source <superscript>129</superscript> Xe image processing pipeline (XIPline) to provide a user-friendly, graphical user interface-based analysis pipeline to analyze and visualize <superscript>129</superscript> Xe MR data, including scanner calibration, ventilation, diffusion-weighted, and gas exchange images.<br />Methods: The customizable XIPline is designed in MATLAB to analyze data from all three major scanner platforms. Calibration data is processed to calculate optimal flip angle and determine <superscript>129</superscript> Xe frequency offset. Data processing includes loading, reconstructing, registering, segmenting, and post-processing images. Ventilation analysis incorporates three common algorithms to calculate ventilation defect percentage and novel techniques to assess defect distribution and ventilation texture. Diffusion analysis features ADC mapping, modified linear binning to account for ADC age-dependence, and common diffusion morphometry methods. Gas exchange processing uses a generalized linear binning for data acquired using 1-point Dixon imaging.<br />Results: The XIPline workflow is demonstrated using analysis from representative calibration, ventilation, diffusion, and gas exchange data.<br />Conclusion: The application will reduce redundant effort when implementing new techniques across research sites by providing an open-source framework for developers. In its current form, it offers a robust and adaptable platform for <superscript>129</superscript> Xe MRI analysis to ensure methodological consistency, transparency, and support for collaborative research across multiple sites and MRI manufacturers.<br /> (© 2024 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
Details
- Language :
- English
- ISSN :
- 1522-2594
- Volume :
- 93
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Magnetic resonance in medicine
- Publication Type :
- Academic Journal
- Accession number :
- 39480807
- Full Text :
- https://doi.org/10.1002/mrm.30347