Back to Search Start Over

Experimental validation of coronary stenosis severity and development of ischemic myocardium.

Authors :
Lee JM
Lee SH
Kwon W
Kim HB
Hong D
Kim HK
Cho SG
Shin D
Park KS
Kim J
Moon JB
Song HC
Lee S
Ha DH
Jang J
Ahn Y
Jeong MH
Choi KH
Park TK
Yang JH
Song YB
Hahn JY
Choi SH
Gwon HC
Hong YJ
Source :
Revista espanola de cardiologia (English ed.) [Rev Esp Cardiol (Engl Ed)] 2024 Oct 28. Date of Electronic Publication: 2024 Oct 28.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

Introduction and Objectives: The current study aimed to evaluate the causal association between hemodynamically significant stenosis and the occurrence of ischemic myocardium using an experimental animal model of coronary artery stenosis.<br />Methods: In Yorkshire swine (n=10), coronary stenosis in the left anterior descending artery was induced using a customized vascular occluder to create varying degrees of occlusion severity (40%-99%). Serial changes in coronary pressure and flow velocity were measured in the left anterior descending artery before and after the implantation of the vascular occluder. At 1 month, <superscript>13</superscript> N-ammonia positron emission tomography (PET) was performed, followed by the collection of isolated hearts for 2,3,5-Triphenyltetrazolium chloride (TTC) staining to quantify the percent area of necrotic myocardium. Three animals in the control group were evaluated using the same protocols, but without the implantation of a vascular occluder.<br />Results: The median diameter stenosis after vascular occluder implantation was 61.3% (Q1-Q3: 55.9%-72.3%). Significant differences were observed in hyperemic stenosis resistance, fractional flow reserve (FFR), stress perfusion defect and reversibility in PET, as well as in necrotic myocardium in TTC staining based on stenosis severity (control group: <50%, 50%-70%, 70%-90%, and >90%) (all P<.010). Animals with FFR <0.75 at 1 month exhibited a significantly higher area of stress perfusion defect (30.7±3.1% vs 6.0±4.2%, P<.001), reversibility in PET (11.0±4.0% vs 0.0±0.0%, P=.006), and necrotic myocardium in TTC staining (15.8±6.4% vs 0.0±0.0%, P<.001) than those with FFR ≥ 0.75.<br />Conclusions: In a porcine model, the induction of hemodynamically significant stenosis with FFR <0.75 was associated with the development of stress perfusion defects and reversibility in PET, as well as necrotic myocardium identified by pathology.<br /> (Copyright © 2024. Published by Elsevier España, S.L.U.)

Details

Language :
English; Spanish; Castilian
ISSN :
1885-5857
Database :
MEDLINE
Journal :
Revista espanola de cardiologia (English ed.)
Publication Type :
Academic Journal
Accession number :
39490529
Full Text :
https://doi.org/10.1016/j.rec.2024.10.006