Sorry, I don't understand your search. ×
Back to Search Start Over

Investigating surface area and recovery efficiency of healthcare-associated pathogens to optimize composite environmental sampling.

Authors :
Chan-Riley MY
Edwards JR
Noble-Wang J
Rose L
Source :
PloS one [PLoS One] 2024 Nov 08; Vol. 19 (11), pp. e0310283. Date of Electronic Publication: 2024 Nov 08 (Print Publication: 2024).
Publication Year :
2024

Abstract

Hospital surfaces are known to contribute to the spread of healthcare-associated antimicrobial pathogens. Environmental sampling can help locate reservoirs and determine intervention strategies, although sampling and detection can be labor intensive. Composite approaches may help reduce time and costs associated with sampling and detection. We investigated optimum surface areas for sampling antimicrobial-resistant organisms (AROs) with a single side of cellulose sponge, created theoretical composites (TC) by adding recovery results from multiple optimum areas, then compared the TC to the standard Centers for Disease Control and Prevention sampling method (one sponge using all sides, whole tool; (WT)). Five AROs were evaluated: carbapenemase-producing KPC+ Klebsiella pneumoniae (KPC), Acinetobacter baumannii (AB), methicillin-resistant Staphylococcus aureus (MRSA), vancomycin-resistant Enterococcus faecalis (VRE) and Clostridioides difficile spores (CD). Steel coupons comprising four surface areas (323; 645; 1,290 and 2,258 cm2) were inoculated, dried, and sampled with one sampling pass using the larger side (face) or the smaller side (edge) of a pre-moistened cellulose sponge tool. Based on the optimum areas determined for each organism, composite areas were 1,290 cm2 for MRSA and VRE, 1,936 cm2 for AB, 2,580 cm2 for CD spores and 3,870 cm2 for KPC. Total colony forming units (CFU) recovered using a composite approach was greater or comparable than using multiple WT samplings (over the same area as the composite) for MRSA, VRE and AB (130%; 144% and 95%) yet less than if using multiple WT samplings for KP and CD (47% and 66%). We propose a conservative composite sampling strategy if the target organism is unknown; 323 cm2 sampling area for each of the four sides of the sponge, (1290 cm2 total). The conservative composite sampling strategy improved the recovery of KP (from 47% to 85% of multiple WT samplings), while MRSA, VRE, AB and CD (131%; 144%; 97% and 66%) remained within 5% to that of the optimum area TC.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 public domain dedication.)

Details

Language :
English
ISSN :
1932-6203
Volume :
19
Issue :
11
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
39514614
Full Text :
https://doi.org/10.1371/journal.pone.0310283