Back to Search Start Over

Effect of CAD-CAM block thickness and translucency on the polymerization of luting materials.

Authors :
Doğu Kaya B
Öztürk S
Şenol AA
Kahramanoğlu E
Yılmaz Atalı P
Tarçın B
Source :
BMC oral health [BMC Oral Health] 2024 Nov 15; Vol. 24 (1), pp. 1384. Date of Electronic Publication: 2024 Nov 15.
Publication Year :
2024

Abstract

Aim: This in-vitro study aimed to evaluate the degree of conversion (DC) of dual-cured luting cement (Bifix QM, VOCO) and flowable composite (Grandio Flow, VOCO) under lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent) and hybrid ceramic (Grandio Blocs, VOCO; Cerasmart, GC) CAD-CAM blocks with different thicknesses.<br />Materials and Methods: Contrast ratio (CR), translucency (TP <subscript>ab</subscript> , TP <subscript>00</subscript> ), and opalescence (OP) parameters of 30 disc-shaped CAD-CAM blocks (n = 5) prepared with two different thicknesses (1.5 and 2 mm) and 8 mm diameters were calculated using a spectrophotometer (VITA Easyshade V, Zahnfabrik). A total of 36 Bifix QM and Grandio Flow samples were prepared at 100 μm thickness using a specific setup by polymerizing from the top of the blocks. Following immersion in distilled water at 37 °C for 24 h, luting materials were examined by Fourier Transform Infrared Spectroscopy for DC calculation. Data were analyzed using One-way ANOVA, Kruskal Wallis, Mann Whitney U, and Independent Samples t-tests (p < 0.05).<br />Results: It was observed that, as the block thickness increased TP <subscript>ab</subscript> , TP <subscript>00</subscript> , and OP decreased, while CR increased. There was no significant difference between the DC of Bifix QM and Grandio Flow when 1.5 mm blocks were used in all groups (p > 0.05). DC of Grandio Flow was significantly higher than Bifix QM under 2 mm-IPS e.max CAD (p = 0.011).<br />Conclusion: The translucency of the CAD-CAM blocks varies depending on their thickness. However, there was no significant difference in the DC of the luting materials depending on the block thickness. Further studies are needed on the use of flowable resin composites as luting material.<br />Competing Interests: Declarations Ethical approval Not applicable. Consent for publication Not applicable. Competing interests The authors declare no competing interests.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
1472-6831
Volume :
24
Issue :
1
Database :
MEDLINE
Journal :
BMC oral health
Publication Type :
Academic Journal
Accession number :
39548438
Full Text :
https://doi.org/10.1186/s12903-024-05171-z