Back to Search Start Over

TAVI with the ACURATE neo2 in severe bicuspid aortic valve stenosis: the Neo2 BAV Registry.

Authors :
Ruck A
Kim WK
Del Sole PA
Wagener M
McInerney A
Yacoub MS
Hasabo EA
Ayhan C
Elzomor H
Neiroukh D
Amir A
Saleh N
Settergren M
Lindler R
Verouhis D
Sossalla S
Renker M
Montorfano M
Bellini B
Suarez XC
Del Olmo VV
De Marco F
Biroli M
Mollmann H
Enno EC
Tarantini G
Fabris T
Ielasi A
Costa G
Barbanti M
Soliman O
Mylotte D
Source :
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology [EuroIntervention] 2024 Nov 24. Date of Electronic Publication: 2024 Nov 24.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

Background: The ACURATE neo2 is a contemporary transcatheter aortic valve implantation (TAVI) system approved for the treatment of severe aortic stenosis in Europe. The ACURATE neo2 has not been evaluated in bicuspid aortic valve (BAV) stenosis.<br />Aims: We sought to evaluate the safety and efficacy of ACURATE neo2 in patients with BAV stenosis.<br />Methods: We retrospectively analysed consecutive severe BAV stenosis patients undergoing TAVI with ACURATE neo2 at 10 European centres. Imaging data from preprocedural multislice computed tomography, pre- and postprocedural echocardiography, and procedural cinefluoroscopy were evaluated by a core laboratory. Valve Academic Research Consortium 3 (VARC-3)-defined 30-day procedure safety and efficacy were the primary endpoints. Adverse events were site-reported according to VARC-3 criteria.<br />Results: Among 181 patients with BAV stenosis treated with the ACURATE neo2, the mean age was 77.5±7.2 years, 58.0% were female, and the Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.3% (1.6-3.7%). Most procedures were transfemoral, and predilatation was performed in all cases. A second valve was required in 4 cases (2.2%). VARC-3-defined technical success was 95.6%. The primary endpoints of device success and early safety occurred in 90.6% and 82.3%, respectively. At 30 days, cardiovascular death occurred in 2.2% (N=4) and stroke in 1.6% (N=3). Core laboratory-adjudicated echocardiography reported an effective orifice area of 2.0 (1.7-2.5) cm <superscript>2</superscript> and a mean transvalvular gradient of 6.5 (4.6-9.0) mmHg. Half of all cases (51.2%) had no paravalvular leak, while moderate leak occurred in 4.3%. A new permanent pacemaker was required in 11 patients (6.5%).<br />Conclusions: The ACURATE neo2 demonstrated favourable clinical outcomes and bioprosthetic valve performance at 30 days in selected patients with severe BAV stenosis.

Details

Language :
English
ISSN :
1969-6213
Database :
MEDLINE
Journal :
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
39582342
Full Text :
https://doi.org/10.4244/EIJ-D-24-00869