Back to Search Start Over

A Comparison of Peripherally Inserted Central Catheter Materials.

Authors :
Ullman AJ
August D
Kleidon TM
Walker RM
Marsh N
Bulmer AC
Pearch B
Runnegar N
Leema J
Lee-Archer P
Biles C
Gibson V
Royle R
Southam K
Byrnes J
Chopra V
Coulthard A
Mollee P
Rickard CM
Harris PNA
Ware RS
Source :
The New England journal of medicine [N Engl J Med] 2025 Jan 09; Vol. 392 (2), pp. 161-172.
Publication Year :
2025

Abstract

Background: New catheter materials for peripherally inserted central catheters (PICCs) may reduce the risk of device failure due to infectious, thrombotic, and catheter occlusion events. However, data from randomized trials comparing these catheters are lacking.<br />Methods: We conducted a randomized, controlled, superiority trial in three Australian tertiary hospitals. Adults and children who were referred for PICC placement were assigned in a 1:1:1 ratio to receive a hydrophobic or chlorhexidine PICC or a standard polyurethane PICC and were followed for 8 weeks. The primary outcome was device failure, which was a composite of infectious (bloodstream or local) or noninfectious (thrombosis, breakage, or occlusion) complications.<br />Results: A total of 1098 participants underwent randomization; 365 were assigned to the hydrophobic group, 365 to the chlorhexidine group, and 368 to the standard-polyurethane group. Device failure occurred in 21 of 358 participants (5.9%) in the hydrophobic group, in 36 of 363 (9.9%) in the chlorhexidine group, and in 22 of 359 (6.1%) in the standard-polyurethane group (risk difference, hydrophobic vs. standard polyurethane, -0.2 percentage points [95% confidence interval {CI}, -3.7 to 3.2; Pā€‰=ā€‰0.89]; and chlorhexidine vs. standard polyurethane, 3.8 percentage points [95% CI, -0.1 to 7.8; Pā€‰=ā€‰0.06]). In the hydrophobic group as compared with the standard-polyurethane group, the odds ratio for device failure was 0.96 (95% CI, 0.51 to 1.78), and in the chlorhexidine group as compared with the standard-polyurethane group, the odds ratio was 1.71 (95% CI, 0.98 to 2.99). Complications from any cause during the period of PICC placement occurred in 77 participants (21.5%) in the hydrophobic group, in 140 (38.6%) in the chlorhexidine group, and in 78 (21.7%) in the standard-polyurethane group (odds ratio, hydrophobic vs. standard polyurethane, 0.99 [95% CI, 0.69 to 1.42]; and chlorhexidine vs. standard polyurethane, 2.35 [95% CI, 1.68 to 3.29]). No adverse events were attributable to the interventions.<br />Conclusions: Among adults and children who were referred for PICC placement, the risk of device failure due to noninfectious or infectious complications was not lower with hydrophobic or chlorhexidine PICCs than with standard polyurethane PICCs. (Funded by the National Health and Medical Research Council of Australia; PICNIC Australian New Zealand Clinical Trials Registry number, ACTRN12619000022167.).<br /> (Copyright © 2025 Massachusetts Medical Society.)

Details

Language :
English
ISSN :
1533-4406
Volume :
392
Issue :
2
Database :
MEDLINE
Journal :
The New England journal of medicine
Publication Type :
Academic Journal
Accession number :
39778170
Full Text :
https://doi.org/10.1056/NEJMoa2406815