Back to Search Start Over

Response of femoral venous oxygen tension to graduated pressure stockings--possible relationship to deep vein thrombosis.

Authors :
Okoye GC
Evans JH
Beattie J
Lowe GD
Lorimer AR
Forbes CD
Source :
Thrombosis and haemostasis [Thromb Haemost] 1984 Feb 28; Vol. 51 (1), pp. 103-4.
Publication Year :
1984

Abstract

Venous oxygen tension (pO2) was measured in discrete samples of blood obtained through the femoral vein of cardiac catheterisation patients before, during and after application of sustained external graduated pressure in the form of compression stockings (T. E. D. Kendall). There was a significant reduction (p less than 0.05) of pO2 from the baseline value both 30 sec and one minute after the application of the pressure stockings. Thereafter, the pO2 rose to baseline values. Two minutes after the stockings were removed there was again a significant reduction (p less than 0.05) of pO2 from the baseline value. We suggest that the decrease in venous pO2 on application of external pressure may be a reflection of washing out of stagnant hypoxic blood from the venous valve pockets, which may be related to the formation of deep vein thrombosis (DVT).