Back to Search Start Over

Different ventilatory approaches to keep the lung open.

Authors :
Sjöstrand UH
Lichtwarck-Aschoff M
Nielsen JB
Markström A
Larsson A
Svensson BA
Wegenius GA
Nordgren KA
Source :
Intensive care medicine [Intensive Care Med] 1995 Apr; Vol. 21 (4), pp. 310-8.
Publication Year :
1995

Abstract

Objectives: To study the ability of different ventilatory approaches to keep the lung open.<br />Design: Different ventilatory patterns were applied in surfactant deficient lungs with PEEP set to achieve pre-lavage PaO2.<br />Setting: Experimental laboratory of a University Department of Anaesthesiology and Intensive Care.<br />Animals: 15 anaesthetised piglets.<br />Interventions: One volume-controlled mode (L-IPPV201:1.5) and two pressure-controlled modes at 20 breaths per minute (bpm) and I:E ratios of 2:1 and 1.5:1 (L-PRVC202:1 and L-PRVC201.5:1), and two pressure-controlled modes at 60 bpm and I:E of 1:1 and 1:1.5 (L-PRVC601:1 and L-PRVC601:1.5) were investigated. The pressure-controlled modes were applied using "Pressure-Regulated Volume-Controlled Ventilation" (PRVC).<br />Measurements and Results: Gas exchange, airway pressures, hemodynamics, FRC and intrathoracic fluid volumes were measured. Gas exchange was the same for all modes. FRC was 30% higher with all post-lavage settings. By reducing inspiratory time MPAW decreased from 25 cmH2O by 3 cmH2O with L-PRVC201.5:1 and L-PRVC601:1.5. End-inspiratory airway pressure was 29 cmH2O with L-PRVC201.5:1 and 40 cmH2O with L-IPPV201:1.5, while the other modes displayed intermediate values. End-inspiratory lung volume was 65 ml/kg with L-IPPV201:1.5, but it was reduced to 50 and 49 ml/kg with L-PRVC601:1 and L-PRVC601:1.5. Compliance was 16 and 18 ml/cmH2O with L-PRVC202:1 and L-PRVC201.5:1, while it was lower with L-IPPV201:1.5, L-PRVC601:1 and L-PRVC601:1.5. Oxygen delivery was maintained at pre-lavage level with L-PRVC201.5:1 (657 ml/min.m2), the other modes displayed reduced oxygen delivery compared with pre-lavage.<br />Conclusion: Neither the rapid frequency modes nor the low frequency volume-controlled mode kept the surfactant deficient lungs open. Pressure-controlled inverse ratio ventilation (20 bpm) kept the lungs open at reduced end-inspiratory airway pressures and hence reduced risk of barotrauma. Reducing I:E ratio in this latter modality from 2:1 to 1.5:1 further improved oxygen delivery.

Details

Language :
English
ISSN :
0342-4642
Volume :
21
Issue :
4
Database :
MEDLINE
Journal :
Intensive care medicine
Publication Type :
Academic Journal
Accession number :
7650253
Full Text :
https://doi.org/10.1007/BF01705409