Back to Search
Start Over
Determination of nicotine and four metabolites in the serum of smokers by high-performance liquid chromatography with ultraviolet detection.
- Source :
-
Journal of chromatography [J Chromatogr] 1993 Nov 24; Vol. 621 (2), pp. 257-61. - Publication Year :
- 1993
-
Abstract
- A simple and reliable reversed-phase high-performance liquid chromatographic method with ultraviolet detection is described for the quantitation of nicotine and its metabolites cotinine, trans-3'-hydroxycotinine, norcotinine and cotinine N-oxide in human serum. The analytes and the internal standard, N-ethylnorcotinine, were extracted by solid-phase extraction before chromatography. Two different columns and mobile phases with gradient systems were used. The detection limit of the assay was 10 ng/ml for nicotine, 3 ng/ml for cotinine N-oxide and 5 ng/ml for cotinine, trans-3'-hydroxycotinine and norcotinine. The concentrations of nicotine and its metabolites in the serum of 12 cigarette smokers are reported.
Details
- Language :
- English
- Volume :
- 621
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Journal of chromatography
- Publication Type :
- Academic Journal
- Accession number :
- 8294547
- Full Text :
- https://doi.org/10.1016/0378-4347(93)80103-b