Quantitative analysis of the tomographic technetium-99m MIBI (99mTc-MIBI) myocardial bullseye display: application to diagnosis of coronary artery disease.

Authors :
Gao ZR
Zhang YX
Hu J
Xu WD
Source :
Journal of Tongji Medical University = Tong ji yi ke da xue xue bao [J Tongji Med Univ] 1995; Vol. 15 (2), pp. 65-7.
Publication Year :
1995

Abstract

In this study, the 99mTc-MIBI myocardial bullseye display of 31 healthy persons and 34 patients with myocardial ischemia and 17 patients with myocardial infarction were analyzed quantitatively; and compared with the results of myocardial tomography analysis and qualitative bullseye analysis. The sensitivities of the three methods were 88.2%, 91.2% and 94.1% respectively (P > 0.05), and the specificities were 93.5%, 83.9% and 83.9% respectively (P < 0.05). On the other hand, the quantitative analysis obviously outperformed the other two methods in the detection of ischemic segments of myocardium near infarction zone (P < 0.01). The quantitative analysis of 99mTc-MIBI myocardial bullseye (quantitative bullseye) was an objective, specific and sensitive method for diagnosis of coronary artery disease.

Details

Language :
English
ISSN :
0257-716X
Volume :
15
Issue :
2
Database :
MEDLINE
Journal :
Journal of Tongji Medical University = Tong ji yi ke da xue xue bao
Publication Type :
Academic Journal
Accession number :
8731954
Full Text :
https://doi.org/10.1007/BF02887903