Changes in the anterior chamber configuration after small-incision cataract surgery with posterior chamber intraocular lens implantation.
- Source :
-
American journal of ophthalmology [Am J Ophthalmol] 1997 Dec; Vol. 124 (6), pp. 775-80. - Publication Year :
- 1997
-
Abstract
- Purpose: To report quantitative changes in the anterior chamber configuration after small-incision cataract surgery with implantation of a posterior chamber intraocular lens by means of ultrasound biomicroscopy.<br />Methods: We examined the anterior chamber configuration of 20 eyes of 20 patients before and 3 months after small-incision cataract surgery (phacoemulsification and aspiration plus foldable intraocular lens implantation through a 3.0- to 4.0-mm self-sealing wound) by means of ultrasound biomicroscopy. The following variables were measured: the anterior chamber depth at the center of the cornea, the angle-opening distance 250 microns from the scleral spur (AOD250), the angle-opening distance 500 microns from the scleral spur (AOD500), and the trabecular-iris angle.<br />Results: The anterior chamber depth at the center of the cornea, AOD250, AOD500, and trabecular-iris angle increased significantly after surgery. The preoperative anterior chamber depth at the center of the cornea and trabecular-iris angle were negatively correlated with the differences between the postoperative and preoperative values (P < .01). The preoperative values of all variables examined were negatively correlated with the ratios of the postoperative value to the preoperative value (P < .002).<br />Conclusions: The present results showed that small-incision cataract surgery significantly deepened the anterior chamber and widened its angle. The more shallow the preoperative anterior chamber was, the greater the postoperative change of the chamber was; and the more narrow the preoperative angle was, the greater the postoperative change of the angle was.
- Subjects :
- Aged
Aged, 80 and over
Anterior Chamber diagnostic imaging
Anterior Chamber surgery
Cornea diagnostic imaging
Cornea surgery
Female
Follow-Up Studies
Gonioscopy methods
Humans
Male
Middle Aged
Ophthalmology methods
Postoperative Period
Prospective Studies
Reproducibility of Results
Ultrasonography
Anterior Chamber pathology
Lens Implantation, Intraocular
Phacoemulsification
Subjects
Details
- Language :
- English
- ISSN :
- 0002-9394
- Volume :
- 124
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- American journal of ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- 9402823
- Full Text :