Back to Search Start Over

[Reconstruction of orbital floor fractures using autologous materials].

Authors :
Le Faou T
Krastinova D
Source :
Revue de stomatologie et de chirurgie maxillo-faciale [Rev Stomatol Chir Maxillofac] 1997 Oct; Vol. 98 (4), pp. 240-2.
Publication Year :
1997

Abstract

Bone and Cartilage Autograft gather all the necessary qualities for an interpositional material to be used in the fractured orbital floor reconstruction, leading to the binocular vision recovery and in term of tolerance. The initial material choice depends on the clinic and orbital tomodensitometry datas, but the final decision is made on the operating findings. However, schematic indications can be drawn up, depending on material characteristics, curve, rigidity and resorption degree, and fracture particularities.