The implementation of in vivo dosimetry in a small radiotherapy department.
- Source :
-
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology [Radiother Oncol] 1998 Apr; Vol. 47 (1), pp. 45-8. - Publication Year :
- 1998
-
Abstract
- Purpose: In vivo dosimetry has been shown in a number of evaluation studies, generally carried out in larger academic centres, to be a reliable method of checking the overall treatment accuracy. The object of this study was to investigate whether it was possible and useful to perform in vivo dosimetry in a small radiotherapy department and to detect if there were any systematic errors in the overall treatment set-up.<br />Materials and Methods: All patients were treated on a cobalt-60 unit equipped with a verification system. Six hundred fifty entrance dose measurements were performed with silicon diodes.<br />Results: The analysis showed a mean deviation of -1.3%. This negative deviation was mainly due to the mean deviation obtained in the treatment of head and neck (-1.6%) or breast (-2.5%) cancer patients. The results for pelvic or lung irradiation showed almost no deviation (-0.8 to 0.43%). Further investigation showed that the negative values for head and neck or breast irradiation were due to the irradiation technique; the lack of scattering material causes a reduction of the dose at the reference point, which is not taken into consideration by the treatment planning system. By performing in vivo dosimetry, we were also able to detect two large errors in 650 measurements and could prevent erroneous treatment.<br />Conclusion: Even when the overall treatment set-up is very accurate, in vivo dosimetry is very useful in a small department since only a small effort can detect and prevent errors.
- Subjects :
- Cobalt Radioisotopes administration & dosage
Feasibility Studies
Health Plan Implementation
Humans
Neoplasms radiotherapy
Quality Assurance, Health Care standards
Radiotherapy, Computer-Assisted methods
Radiotherapy, High-Energy
Reproducibility of Results
Retrospective Studies
Technology, Radiologic instrumentation
Radiology Department, Hospital
Radiotherapy standards
Radiotherapy Dosage
Radiotherapy, Computer-Assisted standards
Subjects
Details
- Language :
- English
- ISSN :
- 0167-8140
- Volume :
- 47
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
- Publication Type :
- Academic Journal
- Accession number :
- 9632291
- Full Text :
- https://doi.org/10.1016/s0167-8140(97)00177-1