Comparison of three different automatic defibrillator implantation approaches: pectoral implantation using conscious sedation reduces procedure times and cost.
- Source :
-
Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing [J Interv Card Electrophysiol] 1997 Nov; Vol. 1 (3), pp. 221-5. - Publication Year :
- 1997
-
Abstract
- Recent technological advances in implantable defibrillator systems (ICD) have changed implantation approaches. The aim of this study was to investigate the influence of these improvements on procedure times, implant-related charges, patient recovery, and morbidity. Ninety-six consecutive patients undergoing implantation of a nonthoracotomy ICD were studied. Implantation was performed under general anesthesia with the generator placed abdominally in 22 patients (group I) and pectorally in 40 patients (group II). Thirty-four patients underwent pectoral implantation using conscious sedation (group III). Groups were comparable with respect to clinical variables. Implantation duration and total procedure duration were shorter in group III (67 +/- 21 minutes and 117 +/- 30 minutes) when compared with group I (100 +/- 25 minutes and 157 +/- 39 minutes) and group II (86 +/- 24 minutes and 153 +/- 34 minutes, P < 0.05). Patients in group III did not require admission to the Post-Anesthesia Care Unit. In contrast, patients in groups I and II spent 92 +/- 28 minutes and 91 +/- 31 minutes in the Post-Anesthesia Care Unit. Implantation-related charges were reduced in patients having pectoral implantation using conscious sedation ($1451 +/- 217 vs. $2354 +/- 550 and $2796 +/- 384, P < 0.05). Patients in group III had a lower frequency of postoperative oral analgesic use (3.2 +/- 2.7 doses, P < 0.05) and a shortened post-operative length of stay (1.9 +/- 1.6 days, P < 0.05) when compared with groups I (5.7 +/- 4.0 doses and 3.3 +/- 1.4 days) and II (5.2 +/- 3.5 doses and 2.6 +/- 1.1 days). The overall complication rate was low (6.3%), with no differences between groups. Advances in ICD technology have simplified implantation, leading to shorter, less painful, and less expensive procedures.
Details
- Language :
- English
- ISSN :
- 1383-875X
- Volume :
- 1
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing
- Publication Type :
- Academic Journal
- Accession number :
- 9869975
- Full Text :
- https://doi.org/10.1023/a:1009768806894